It is essential to correctly connect the retarder-proofer/dough retarder table and cabinet to an
efcient earthing system carried out as specied by the applicable provisions of law.
14.1 Connection to the water supply (retarder-proofer solely)
All models of retarder-proofer/dough retarder refrigerated table and refrigerated cabinet need to
be connected to a water supply to perform the functions of management and control of humidity.
The connection to water supply must be made according to the manufacturer’s instructions and by
professionally qualied personnel. The tting of 3/4 for the connection to the water supply is located
in the condensing unit of the retarder-proofer cabinets, in the rear, close to the housing of the power
supply cable at an height from the ground of cm 190. This unit must only be supplied with cold water,
not distilled or demineralized.
The operating pressure should be between 0.1 and 0.5 MPA. Between the water network and the
load connection of the equipment 3/4 should be installed a tap to interrupt the passage of water in
case of need. In the case the water is hard it is advisable to install a water softener, the presence of
solids such as sand can be eliminated by installing a mechanical lter to be inspected and cleaned
periodically.
CHAPTER 15 INSTALLATION OPERATIONS
It is important, in order to prevent errors and accidents, to perform a series of checks before starting
up the the retarder-proofer/dough retarder table and cabinet in order to identify any damage incurred
during transport, handling and connection.
Checks to be performed:
- check the integrity of the power cord (it must not have suffered abrasions or cuts)
- check the solidity of the legs, door hinges, shelf supports
- check the integrity of the internal and external parts (pipes, heating elements, fans, electrical
components, etc.) and their xing
- check that the seals of the doors and drawers have not been damaged (cuts or abrasions) and
close with an airtight seal
- check the integrity of the pipes and ttings (REM)
CHAPTER 16 REINSTALLATION
It is necessary to comply with the following procedure:
- disconnect the power cord from the power outlet
- the handling should be carried out as described in chapter 13
- for a new placement and connection, please refer to par. 13.1
- for the REM models proceed to the possible recovery of the coolant gas in accordance with the
regulations in force in your country