After send the above command, the tracker will send the heartbeat packet to the platform every 1 hour in PS1 and PS0 mode. The heartbeat function is used
to keep the platform connection smooth, but GPS positioning data is invalid.
Command: HB00M
When the interval is 00, the heartbeat packet function is disabled.
6. Setting reporting time interval when no movement
When device has no movement for 5 minutes, GPS chip go to sleep. the time to send data to platform can be configured by user. (Once device detect
movement, the time to send data to the platform will back to normal reporting time interval(TIxxS/M/H) )
Command: NMxxM/H
Note: xx=00~99, M=Minute, H=Hour
Example: NM90M
After send the above command, device will transmit data every 90 minutes to the platform when device no motion.
7. Check APN & IP, Port
Command: G1
The device will reply “APN: internet; Name: xxx; Password: xxxx; Port: 5050; IP:www.smart-tracking.com”
8. Change IP and Port
Command: IP1,IP/domain name,port
Example: IP1,103.21.211.11,5050 or IP1,www.smart-tracking.com,5050