EasyManua.ls Logo

Evinrude E-TEC G2 - Page 62

Evinrude E-TEC G2
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
60
Maintenance
Outboard continues to run at slow idle
speed.
3) After outboard runs for another 15 sec-
onds:
For side mount controls, fully raise the
fast idle lever again.
For binnacle or concealed side mount
controls, fully advance throttle handle
again.
Outboard will accelerate to fast idle speed
and fog itself.
4) Allow outboard to run until it shuts itself
OFF automatically (one to two minutes).
Tiller Control Outboards
1) Fully advance throttle grip. Start the out-
board. Outboard runs at slow idle speed.
2) After outboard runs for at least 15 seconds,
move throttle grip to IDLE position. Out-
board continues to run at slow idle speed.
3) After outboard runs for another 15 sec-
onds, fully advance the throttle grip again.
Outboard will accelerate to fast idle speed
and fog itself.
4) Allow outboard to run until it shuts itself
OFF automatically (one to two minutes).
006458
006459
Winterization is complete when outboard
shuts itself off.
If the outboard DOES NOT shut itself
off, you may not have used the fast idle le-
ver or button and the outboard was shifted
into gear.
If the engine exceeds 3000 RPM, the out-
board may have been shifted into gear.
In either event, immediately turn the key
switch OFF and re-start the procedure.
Tiller Control – Typical 007036
007037
007038
Winterization is complete when outboard
shuts itself off.
If the outboard DOES NOT shut itself
off, you may not have properly advanced
throttle grip.
If the engine exceeds 3000 RPM, the out-
board may have been shifted into gear.
In either event, immediately press the engine
cut–off switch to turn outboard OFF and re-
start the procedure.

Table of Contents