EasyManua.ls Logo

Evolution Dog wash - Pump Priming

Evolution Dog wash
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Evolution Dog Wash Owners/Operators Manual Page 30
5.2.3.1 Pump Priming
During the Quality Control check prior to shipping, each pump is activated, set to the
proper dosing measure, and primed with water. This will allow you to place the proper
product suction hose into the proper product and begin using the EVOLUTION. It will
take several minutes for the product to be provided to the pump through the hose. In
the event the pump needs to be primed follow these procedures:
1. Ensure the product suction hose, foot valve, and cap have been installed.
2
. T
urn on the unit using the operator switch.
3
. C
hoose the product to be primed on the selection switch on meter.
4
. O
pen the bleeder valve by turning counterclockwise.
5
. I
ncrease the stroke speed by pressing the up arrow to 360 strokes/min.
6. Observe the product coming up the suction hose. (See Below)
7
. W
hen product reaches pump close bleeder valve.
8
. D
ecrease the stroke speed by pressing the down arrow to original setting.
9. Turn product selection to the off position and turn off operator switch.
In the event that the pump will not prime, perform the steps on the next page.
S
uction Hose Parts Description
Injector Hose
Bleeder Hose
Dosing Pump
Product Suction Hose
Bleeder Valve
Pump Components
And Connections
Suction Hose Nut
Suction Hose Nut
Suction Hose
Ferrule
Swedge Fitting
O-Ring