113
Calling the panel
When a telephone number that has been programmed into the
system calls the central unit, a two-way voice connection is
automatically established. Allows the operator to listen, talk or
have two-way conversations with people in the building.
PROBLEM SOLVING
AC power outage: If there is a power outage in the building
and/or surrounding area, the system will run on batteries for
several hours.
Low system battery: "Low Battery" is displayed when the system's
backup battery is low.
Sensor battery is dead: Each wireless sensor in the system has an
internal battery. The system detects a low battery condition in the
wireless sensors and displays the message "Sensor with low
battery" on the home screen, indicating that the battery in that
sensor(s) needs to be replaced within 7 days.
Tamper switch: when a tamper is detected, a "Tamper" alarm is
generated.
SPECIFICATIONS
Safety panel
• Primary performance: Power supply, micro USB 110/220VAC to
5VDC, 1A output
• Battery backup: 3.7V/1000Ah lithium battery
• Consumption: <150mA@normal
• Siren output: <300 mA
• Radio frequency: 315/433/868/915Mhz (optional)
• RF code: eV1527