set to "0" is +-10% of the
nominal supply (207-
253VAC). Values of 1-23
are allowed, which expand
both lower and upper
threshold by the respective
amount in VAC.
GetConfigurationMaxKeys
yes
5
The number of OCPP
configuration keys that can
be acquired from a single
get configuration command.
HeartbeatInterval
yes
60
The interval between each
heartbeat PDU.
LightIntensity
yes
100
The light intensity of the
LED ring of the charger in %
of maximum.
LocalAuthListEnabled
FALSE
LocalAuthListMaxLength
0
LocalAuthorizeOffline
TRUE
LocalPreAuthorize
FALSE
MaxChargingProfilesInstalled
10
MeterValueSampleInterval
yes
60
The time interval between
each meter value during a
session.
MeterValuesSampledData
yes
Voltage.L1-
N,Voltage.N,Te
mperature,Cur
rent.Offered.L
1,Current.Impo
rt.L1,Power.Ac
tive.Import.L1,
Energy.Active.I
mport.Register
.L1
A list of measurands sent for
each meter value during a
session.
NumberOfConnectors
1
SendLocalListMaxLength
0
StopTransactionOnEVSideDisconnect
TRUE
StopTransactionOnInvalidId
TRUE
UnlockConnectorOnEVSideDisconnect
yes
TRUE
When set to TRUE the
Charge Point SHELL unlock
the connector on Charge
Point side when the cable is
unplugged at the EV
c_MainOfflineTimeout
yes
yes
null
Defines the timeout value
for the main communication
network interface
c_FallbackOfflineTimeout
yes
yes
null
Defines the timeout value
for the fallback
communication network
interface
c_FallbackOnlineTimeout
yes
yes
null
Defines the duration for
which the fallback network
interface is active before
reverting to the main
network interface
C_OCPPNetLog
yes
yes
FALSE
Configures whether