diagnostic network data logs
are sent via OCPP
c_ChargeOffPeriod1
yes
yes
enable,08:00,1
1:00
Defines the first standard
period for offline charging
c_ChargeOffPeriod2
yes
yes
enable,16:00,2
2:00
Defines the second standard
period for offline charging
c_MaxStartDelay
yes
yes
600
Defines the maximum value
for the randomized delay
functionality for offline
charging
c_LockerDisengage
yes
yes
TRUE
Defines whether the built-
in locker is enabled or
disabled.
c_CTClamp
yes
yes
FALSE
Presence or absence of a CT
clamp
c_CTClampValue
yes
yes
65535
Defines the value range of
the CT clamp measurand
data
c_MainNetworkInterface
yes
yes
0
Defines the main network
interface
c_FallbackNetworkInterface
yes
yes
0
Defines the fallback
network interface
c_APN
yes
yes
0
Sets or gets the APN used
for cellular network
interface