In this Param Set interface, with: Param Set/Charger system/Local Authorize Enabled, if we disabled it,
then we can realize one key start charging function with no any authority.
In this Param Set interface, with: Param Set/CCU Group/Charger/CCU Specific Settings/Power Merging Mode,
we can choose the different type of the charging power sharing:
1. Stand alone (each two charging cable share half system power, and no power sharing)
2. Cut when Current Decrease (First EV will have all the system power, till the charging power decrease as the
requirement from the EV BMS, and have half power release, then the charger will switch half power to the other
charging cable and enable the second EV charging).
3. Cut when plug in (First EV will have all the system power, but as the second EV plug in,the charger will switch
half power to this EV and enable the second EV charging).
4. First come first serve (First EV will have all the system power till finish the charging, and then can switch the
power to the second EV and enable the second EV charging).
5. One car with two connectors (This mode is special for the EV which has two charging connectors, we can
plug the charger’s two charging cable in to the same EV’s two charging connectors, and enable the full power of the
charger to charge the EV, and no limitation from the normal one charging cable’s max current (200A), that can get
400A max charging current.