OFFICE LINE
26
CLEANING AND MAINTENANCE
Cleaning the brewing group and portafilter
Unlock and remove the portafilter from the group head.
Place the cleaning membrane in the filter basket.
Fill the filter basket with professional cleaning powder for espresso coffee machines.
Lock the portafilter into the group head.
Ofce Control machines: To activate the auto-cleaning program turn off the machine’s main power
switch. Then press and hold the 2 Short Espressos button then turn on the main power
switch. Cleaning will start automatically. Release the 2 Short Espressos button.
Office Pulser machines: To activate the auto-cleaning program simply cycle the Brew button on
for 5 intervals of 10 seconds each.
Leva Pulser machines: To activate the auto-cleaning program simply raise the brew lever for 5
intervals of 10 seconds each.
Cleaning membrane
Espresso-machine
detergent
Note:
Only use professional cleaning
powder for espresso machines.
It’s available from your
distributor. Part no: 1104162
i
WARNING!
Never try to open the portalter while the machine is in operation! The pressurised hot
water could cause scalding or serious injury. After cleaning has nished, wait about 3
seconds before removing the portalter.
Important:
When the cleaning process is nished, remove the portalter and run water through
the group again to rinse out any residue. Repeat the cleaning process this time without
cleaning powder to remove any remaining residue. Store the cleaning membrane in a
convenient location for future use.
Note:
Rinse the group and portalter with hot water (using only the cleaning membrane and
hot water, no cleaning powder) each day that the machine is used.
Clean the group and portalter with cleaning powder once a week.
i