USERGUIDE
SalinityMeter
PenStyleWaterQualityMeter
ModelEC170
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Questions and Answers:

Extech Instruments EC170 Specifications

General IconGeneral
BrandExtech Instruments
ModelEC170
CategoryMeasuring Instruments
LanguageEnglish

Summary

Features

IP65 Waterproof housing

Meter has an IP65 rated water-proof enclosure for safety.

Automatic and Manual Ranging

Supports both automatic and manual selection of measurement ranges.

Dual Display with ATC

Features a dual display with Automatic Temperature Compensation.

Data hold

Allows freezing displayed readings for later review.

Low battery indicator

Provides an indicator for low battery status.

Automatic power-off

Meter automatically powers off after inactivity to save battery.

Switchable temperature units

Allows switching between Celsius and Fahrenheit temperature units.

Multi-point calibration

Offers multi-point and one-touch calibration features.

Pocket sized design

Compact and pocket-sized design for portability.

Supplied Materials

EC170 meter

The Extech EC170 Salinity Meter unit.

LR44 button batteries

Includes four LR44 button cell batteries for power.

Operation manual

Includes a manual for operation, available in multiple formats.

Battery Installation

Unscrew battery compartment

Instructions to unscrew the battery compartment cover counter-clockwise.

Install LR44 batteries

Guide for correctly installing the LR44 batteries, observing polarity.

Replace battery cover

Steps to replace the battery compartment cover after installation.

Remove batteries for long periods

Recommendation to remove batteries when the meter is not in use for extended periods.

Battery disposal guidelines

Guidelines for proper disposal of batteries and the instrument.

Battery safety reminders

Important safety reminders regarding battery handling and usage.

Meter Description

Battery Compartment

Location of the meter's battery compartment.

Display overview

The main screen of the meter showing measurements and icons.

Keypad overview

The buttons used to operate the meter.

Electrode

The sensor part of the meter for taking measurements.

Electrode protective cap

The cap used to protect the electrode when not in use.

Display Description

Data Hold icon

Icon indicating that the displayed reading is frozen.

Primary measurement display

The main display area for the measured value.

Salinity units (ppt)

Units for salinity measurement (parts per thousand).

Temperature reading display

The displayed temperature value.

Temperature units indicator

Indicates whether temperature is shown in °C or °F.

Battery strength indicator

Shows the current battery level.

Calibration icon

Icon indicating the calibration status.

Keypad Description

Power ON-OFF/SET button

Button for turning the meter on/off and setting parameters.

Down Arrow/Data Hold/CAL button

Button for navigation, data hold, and calibration.

Up arrow button

Button for navigation.

Operation

Getting Started

Initial steps to prepare and turn on the meter.

Automatic and Manual Ranging

Explanation of how to select measurement ranges.

Measurement Preparations

Accuracy considerations

Notes on factors affecting measurement accuracy.

Probe rinsing and soaking

Procedures for rinsing and soaking the electrode before use.

Eliminating air bubbles

Steps to remove air bubbles from the probe.

Homogenizing sample

Ensuring sample homogeneity and waiting for temperature equilibrium.

Freezing displayed reading

Using the HOLD button to freeze readings.

Salinity Measurement

Insert electrode into sample

Instructions for immersing the electrode in the sample.

Stir solution to remove bubbles

Stirring the solution with the electrode to remove air bubbles.

Meter auto-range display

How the meter finds range and displays results.

Finishing a Measurement

Rinse and store electrode

Proper cleaning and storage of the electrode.

Affix protective cap

Replacing the protective cap on the electrode.

Automatic Power OFF

Disable Sleep Mode

How to disable the automatic power-off feature.

Setup Mode

Parameter P1: Temperature Units

Setting the temperature units (°C/°F).

Parameter P3: Factory Default Reset

Restoring the meter to its factory default settings.

Parameter P4: Calibration Review

Reviewing previous calibration data for ranges.

Calibration

Calibration Preparation

Determining calibration schedule and standards.

Calibration Schedule

Recommended frequency for calibration.

Selecting Calibration Standard

Guidance on choosing appropriate calibration solutions.

Salinity Calibration Procedure

Rinse probe with water

Initial rinsing of the probe in deionized water.

Select Sodium Chloride standard

Choosing the correct standard solution.

Prepare sample cups

Filling sample cups with standardizing solution.

Rinse probe in solution

Rinsing the probe in the calibration solution.

Dip probe into solution

Immersing the probe in the standard solution for measurement.

Activate CAL mode

Pressing HOLD/CAL to enter calibration mode.

Adjust displayed value

Using arrow buttons to match the displayed value to the standard.

Confirm calibration value

Pressing SET to confirm the calibration value.

Handling calibration outside ±30%

Procedures for values outside the acceptable calibration window.

Maintenance

Keep electrode clean

Instructions for cleaning the measurement electrode.

Store electrode carefully

Proper methods for storing the electrode.

Troubleshooting

Power ON no display

Steps to resolve no display issues when powering on.

Display switches OFF

Explanation and resolution for the display switching off.

Air Bubbles on Electrode

Tips for preventing and removing air bubbles on the electrode.

Error Codes

Salinity Errors

Codes and suggestions for salinity measurement errors.

Temperature Errors

Codes and suggestions for temperature measurement errors.

Factory Default Settings

P1.0 Temp Units Default

Default setting for temperature units is Celsius.

P3.0 Factory Reset Default

Default setting is NO for reverting to factory defaults.

P4.1 Calibration Data Range 1

Default shows calibration data for Range 1.

P4.2 Calibration Data Range 2

Default shows calibration data for Range 2.

Specifications

Measurement ranges

Specifies the salinity measurement ranges (0.00-10.00 ppt and 10.1-70.0 ppt).

Salinity Accuracy

Details the accuracy for each salinity measurement range.

Salinity Resolution

Specifies the resolution for salinity measurements.

Temperature Accuracy

Accuracy of the temperature measurement.

Temperature Resolution

Resolution of the temperature measurement.

TDS Factor

Indicates the built-in NaCl conductivity to TDS conversion factor.

Calibration process

Notes that calibration is one point per range.

Auto Power OFF time

Specifies the auto power off time as 20 minutes.

Data Hold function

Defines Data Hold function as freezing displayed readings.

ATC operating range

Specifies the ATC operating range.

Waterproof rating

States the meter is IP65 rated.

Temperature Coefficient

Mentions the built-in NaCl temperature coefficient.

Operating Conditions

Details the recommended operating temperature and humidity.

Storage Conditions

Details the recommended storage temperature and humidity.

Normalization Temperature

Specifies the fixed normalization temperature.

Status Indicators

Lists indicators like out-of-range and low battery.

Power Supply

Specifies the power source as four LR44 batteries.

Dimensions

Provides the physical dimensions of the meter.

Weight

Specifies the weight of the meter.

Related product manuals