Do you have a question about the Extech Instruments EN510 and is the answer not in the manual?
Type | Environmental Meter |
---|---|
Resolution (Temperature) | 0.1 °F/°C |
Resolution (Humidity) | 0.1% RH |
Data Hold | Yes |
Operating Temperature | 32 to 122 °F (0 to 50 °C) |
Battery Life | Approximately 100 hours |
Resolution (Air Quality) | 1ppm |
Accuracy (Temperature) | ±1.8 °F (±1 °C) |
Accuracy (Humidity) | ±3%RH |
Display | LCD |
Operating Humidity | 10 to 90%RH |
Temperature Range | 14°F to 140°F (-10°C to 60°C) |
Welcomes the user and outlines the capabilities of the Extech EN510 Environmental Meter.
Lists professional, customizable features, selectable units, and various measurement capabilities for environmental monitoring.
Provides essential safety precautions for operating the environmental meter, including reading the manual and handling the device.
Identifies key external components of the environmental meter, including the vane, input, display, buttons, and sensors.
Details the various icons and indicators on the LCD screen, such as MAX/MIN, HOLD, units of measure, and temperature displays.
Describes how to power the meter on/off using the power button and the automatic power-off feature to conserve battery life.
Explains how to navigate and select different measurement modes (Anemometer, Air Flow, RH, etc.) using the Mode button.
Details the procedure for changing measurement units for air velocity, air flow, temperature, and light on the meter.
Explains the LCD's automatic orientation reversal for improved viewing and how to use the backlight feature.
Describes how to freeze the displayed reading using the Hold button and its operational limitations.
Explains how to record, toggle, and reset maximum and minimum readings over time using the Record button.
Details how to perform Air Velocity, Light, and various Environmental measurements (RH, Dew Point, etc.).
Explains how to measure air flow in CFM and CMM, including duct area calculation and unit conversion.
Covers essential maintenance tasks such as battery replacement, cleaning, and proper storage of the meter.
Lists general technical specifications of the meter, including display, sensors, power, weight, and dimensions.
Details the range, resolution, and accuracy for air velocity and temperature measurements in various units.
Details specifications for relative humidity and air temperature, including range, resolution, and accuracy.
Provides specifications for light measurements in Lux and Foot-candles, including range, resolution, and accuracy.
Lists specifications for Air Flow (CMM, CFM) including range and resolution.
Specifies the range, resolution, and accuracy for Dew Point and Wet Bulb temperature measurements.
Provides specifications for Heat Index and Type K thermometer measurements, including accuracy.
Details specifications for Wind Chill measurements in Celsius and Fahrenheit, including accuracy and display conditions.
A table converting units for air velocity measurements such as m/s, ft/min, knots, km/h, and MPH.