SDL600-EU-EN-V1.2-10/11
Datalogging and PC Interface
Types of Data Recording
Manual Datalogging: Manually log up to 99 readings onto an SD card via push-button press.
Automatic Datalogging: Automatically log data onto an SD memory card where the number of
data points is virtually limited only by the card size. Readings are logged at a rate specified by
the user.
SD Card Information
Insert an SD card (from 1G size up to 16G) into the SD card slot at the bottom of the meter. The
card must be inserted with the front of the card (label side) facing toward the rear of the meter.
If the SD card is being used for the first time it is recommended that the card be formatted and
the logger’s clock set to allow for accurate date/time stamping during datalogging sessions.
Refer to the Setup Mode section for SD card formatting and time/date setting instructions.
European and USA numerical formats differ. The data on the SD card can be formatted for
either format. The meter defaults to USA mode where a decimal point is used to separate units
from tenths, i.e. 20.00. The European format uses a comma, i.e. 20,00. To change this setting,
refer to the Setup Mode section.
Manual Datalogging
In the manual mode the user presses the LOG button to manually log a reading onto the SD card.
1. Set the sampling rate to ‘0’ seconds as described in the Setup Mode section.
2. Press and hold the LOG button for at least 1.5 seconds and the DATALOGGER icon will
appear on the LCD; the lower portion of the display will show ”P N” (N = memory position
number 1-99).
3. Momentarily press the LOG button to store a reading. The DATALOGGER icon will flash each
time a data point is stored.
4. Use the and buttons to select one of the 99 data memory positions in which to record.
5. To exit the manual datalogging mode, press and hold the LOG button for at least 1.5 seconds.
The DATALOGGER icon will switch off.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extech Instruments SDL600 and is the answer not in the manual?

Extech Instruments SDL600 Specifications

Display IconDisplay
display size52 x 38mm (2 x 1.5”) Backlit LCD
display update rateApprox. 1 second
Microphone IconMicrophone
microphone type12.7mm (0.5”) electret condenser microphone
microphone diameter12.7mm (0.5”) outer diameter
Measurement IconMeasurement
measurement unitsDecibels
measurement ranges30 to 80, 50 to 100, and 80 to 130dB
frequency range31.5Hz to 8KHz
Power IconPower
power supplySix (6) 1.5 VDC batteries (optional 9V AC adaptor)
power consumption (normal operation)approx. 12mAdc
power consumption (backlight off, datalogging on)approx. 51mAdc
Operating Environment IconOperating Environment
operating temperature0 to 50°C (32 to 122°F)
operating humidity85% R.H. max.
auto power offAfter 10 minutes of inactivity (can be disabled)
Weight and Dimensions IconWeight and Dimensions
weight428g (0.94 lbs.) including batteries
main instrument dimensions250 x 73 x 47.5mm (9.8 x 2.9 x 1.9”)