4 SDL700-EU-EN V1.4 03/12
Setup Mode
Basic settings at a glance
To view the current configuration of the meter with regard to time, date, and datalogging sampling
rate press the SET button momentarily. The meter will now display the configuration in quick
succession. If the information is missed on the first try, simply press the SET button again until all of
the information is noted.
Accessing the Setup mode
1. Press and hold the SET button for at least 1.5 seconds to access the Setup menu.
2. Press the SET button momentarily to step through the available parameters. The parameter
type is shown on the bottom of the LCD and the current selection for that type is shown above
it.
3. When a parameter is displayed that is to be changed, use the arrow keys to change the
setting. Press the ENTER button to confirm a change.
4. Press and hold the SET button for at least 1.5 seconds to exit the Setup mode. Note that the
meter automatically switches out of the Setup mode if no key is pressed within 7 seconds.
5.
The available Setup parameters are listed below. Additional detailed information is provided
below this list:
dAtE
Set the clock (Year/Month/Date; Hours/Minutes/Seconds)
SP-t
Set the datalogger sampling rate (Hours/Minutes/Seconds)
PoFF
Automatic power-off management (Enable or disable the auto-power off function)
bEEP
Set the beeper sound ON/OFF
dEC
Set the numerical format; USA (decimal: 20.00) or European (comma: 20,00)
Sd F
Format the SD memory card
tYPE
Select the pressure range type (
2, 5, 10, 20, 50, 100, 200, and 400 Bar
)
Setting the Clock Time
1. Access the dAtE parameter.
2. Use the arrow keys to change a value
3. Use the ENTER button to step through the selections
4. Press and hold the SET button for at least 1.5 seconds to exit to the normal operation mode (or
simply wait 7 seconds for the meter to automatically switch to the normal operating mode).
5. The clock will keep accurate time even when the meter is switched off. However, if the battery
expires the clock will have to be reset after fresh batteries are installed.
Setting the Datalogger Sampling Time (Rate)
1. Access the SP-t parameter.
2. The sampling rate can be set from ‘0’ seconds (manual log mode) up to 8 hours, 59 minutes,
and 59 seconds.
3. Use the ENTER button to move through the Hours, Minutes, and Seconds digit groups and use
the arrow keys to change the digit values.
4.
Press the ENTER button to confirm the entry.
5. Press and hold the SET button for at least 1.5 seconds to exit to the normal operation mode (or
simply wait 7 seconds for the meter to automatically switch to the normal operating mode).
netzerotools.com
netzerotools.com
Question and Answer IconNeed help?

Do you have a question about the Extech Instruments SDL700 and is the answer not in the manual?

Extech Instruments SDL700 Specifications

General IconGeneral
DisplayLCD
Data LoggingYes
Sound Level Range30 to 130dB
Light Range0 to 20, 000 Lux
Resolution (Sound)0.1dB
Resolution (Light)1 Lux
Resolution (Humidity)0.1%RH
Resolution (CO2)1ppm
Measurement Range (Light)0 to 20, 000 Lux
Resolution (Light Meter)1 Lux
Resolution (Temperature)0.1°F / 0.1°C
Sampling Rate1 second
Humidity Range10 to 90%RH
Accuracy (Light)±5%
Accuracy (Humidity)±3% RH
Accuracy (Light Meter)±5%

Summary

Introduction and Safety

International Safety Symbols

Symbol indicates user must refer to manual for further information.

Meter Description

Getting Started

Power ON-OFF

Instructions for powering the meter on and off using the power button.

Display Backlight

How to turn the display backlight on or off using the backlight button.

Pressure Sensors

Information on connecting and selecting pressure sensors for the meter.

Units of Measure

How to change the displayed unit of measure using the UNIT button.

ZERO Adjustment

Procedure to null or zero the display for a connected sensor.

Data Hold

How to freeze a displayed reading on the LCD using the HOLD button.

Setup Mode Functions

Accessing the Setup Mode

Step-by-step guide to enter and navigate the meter's setup menu.

Setting the Clock Time

Instructions for setting the date and time parameters on the meter.

Setting the Datalogger Sampling Time (Rate)

Procedure to configure the sampling interval for data logging.

Auto Power OFF Feature

How to enable or disable the automatic power off function.

Beeper Sound ON/OFF

Instructions to set the beeper sound on or off.

Numerical Format Setting

How to select between USA (decimal) and European (comma) numerical formats.

SD Card Formatting

Procedure to format the SD memory card for use with the meter.

Pressure Sensor Range Type

How to select the appropriate pressure sensor range type for the meter.

System Reset

Instructions for resetting the instrument using the reset button.

Max-Min Reading Record

Datalogging Operations

Manual Datalogging

How to manually log up to 99 readings onto an SD card via button press.

Automatic Datalogging

How to automatically log data onto an SD card at a user-specified rate.

SD Card to PC Data Transfer

Instructions for transferring logged data from the SD card to a PC.

Connectivity and Power

RS-232/USB PC Interface

Information on using the optional software and cable for PC data streaming.

AC Power Adaptor

Details regarding the optional 9V power adaptor for meter operation.

Battery Replacement and Disposal

Instructions for replacing batteries and proper disposal guidelines.

Specifications

Transducer Range and Resolution

Related product manuals