22 DTP CrossPoint 4K Series • Remote Control
Remote Control
This section describes using the remote control features of the
DTP CrossPoint 4K Series. Topics that are covered include:
Selected SIS Commands
Installing and Starting the Control Programs
Accessing the HTML Pages
Selected SIS Commands
You can use Simple Instruction Set (SIS) commands for operation
and conguration of the switchers (see SIS Command and
Response Table for Matrix Switcher Commands on page 24).
You can run these commands from the PC connected to an
Ethernet port (
item
Q
or item
R
on page 10), serial port (item
S
on page 10), or USB port (item
A
on page 16) on the switcher.
Establishing a Network (Ethernet) Connection
NOTE: The first time you connect to the switcher via the LAN
port, you may need to change the default settings (IP address,
subnet mask, user name, and administrator or user password)
of the IPCP controller or switcher.
Establish a network connection as follows:
1. Open a TCP socket to port 23 using the switcher IP address.
NOTE: The factory default IP address is 192.168.254.254.
The switcher responds with a copyright message including the
name, rmware version, and part number of the product, and
the current date and time.
NOTES:
If the switcher is not password-protected, the device is
now ready to accept SIS commands.
If the switcher is password-protected, a password
prompt appears.
2. If necessary, enter the appropriate password.
If the password is accepted, the switcher responds with Login
User or Login Administrator.
If the password is not accepted, the Password prompt
reappears.