Input Voltage 115 V~ ± 10% or
230 V~ +6% -10%
50/60 Hz
Input Power 10 W
Motor Max. Load 800 W
Accessories Max. Load 0,5 A
Electric Lock Max. Load 15 VA
Ambient Operating Temperature Range -4°F to +131°F
Protection Fuses 5A (230V version)
10A (115V Version)
800 mA (accessory)
DL STATUS AND PROGRAMMING DISPLAY
J1 LOW VOLTAGE TERMINAL BLOCK
J2 CONNECTOR FOR RADIO RECEIVER
J3 AC POWER SUPPLY TERMINAL BLOCK
J4 MOTORS AND WARNING LAMP TERMINAL BLOCK
J5 INDICATOR-LIGHT AND ELECTRIC LOCK TERMINAL BLOCK
J6 LIMIT-SWITCH TERMINAL BLOCK
F1 MOTORS AND TRANSFORMER PRIMARY WINDING
FUSE (F 5A - 230V) (F 10A - 115V)
F2 LOW VOLTAGE AND ACCESSORIES FUSE (T 800mA)
F “F” PROGRAMMING PUSH-BUTTON
– “–” PROGRAMMING PUSH-BUTTON
+ “+” PROGRAMMING PUSH-BUTTON
3. Features
Function Logics:
Semi-automatic / Automatic / Safety Devices / “Stepped” Semi-
automatic / “Stepped” Automatic / “Stepped” Safety Devices /
Semi-automatic B / Dead-man C
Opening/Closing Time:
Programmable (from 0 to 120 s)
Pause Time:
Programmable (from 0 to 4 min.)
Closing Leaf Delay:
Programmable (from 0 to 4 min.)
Opening Leaf Delay:
2 s (can be excluded)
Thrust Force:
Adjustable on 50 levels for each motor
Terminal Board Inputs:
Open / Open Free Leaf / Stop / Limit-switch / Opening Safety Devi-
ces / Closing Safety Devices / Power Supply + Earth.
Terminal Board Outputs:
Flashing Lamp / Motors / 24 VDC Accessories Power Supply / 24 VDC
Indicator-Light / Fail Safe / 12 VAC Electric Lock Power Supply
Programmable Functions:
Logic / Pause Time / Thrust Force / Torque at Initial Thrust / Opening and
Closing Leaf Delay / Reversing Stroke / Over-Pushing Stroke / Indicator-
Light / Pre-Flashing / Electric Lock / Fail Safe / Safety Devices Logic
/ Assistance Request / Detection Time of Obstacle or Contact Point
Learning Function:
Simple or complete work time learning, with or without Limit-switches
Terminal Block J3 - Power Supply
PE:
Earth Connection / Ground
N: AC V~ power supply (Neutral)
L: AC V~ power supply (Line)
Connector J2 - Rapid Connection to RP Receivers
455 D
RP 418 DS
RP 433 RC
1. General Description
The 455 D control board is used to operate the FAAC High
Voltage swing gate operators. It has several operating logics
built in, programmable with the help of a display and push-
buttons. The board allows connection of various accessories
including monitored photocell for compliance with the
UL325 standard Ed: 6.
The 455 D control board should be installed in an enclosure
that is conveniently located as close as possible to the gate
operator. All electrical connections from the control board
to the operator must be made in a weatherproof junction
box.
The 5 pin J2 connector allows to plug in the FAAC RP radio
receivers
455D CONTROL BOARD
2. Technical Specifications
4. Layout and Components