FAAC 400 - Description Technical Specifications; Dimensions; Wiring

FAAC 400
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
15 AWG
20 AWG
15 AWG
15 AWG
20 AWG
20 AWG
15 AWG
20 AWG
3
11/32”
3
11/32”
4
3/4”
MODEL CBC CBAC SB SBS
CBAC
R
CBAC
EG
SB
EG
Max Traction / Thrust
Force: (daN)
620 620 620 775 465 465 465
Effective Rod Stroke:
(inches)
10 1/4 10 1/4 10 1/4 10 1/4 10 1/4 15 15
Linear Rod Speed:
(inches/sec)
0.4 0.4 0.4 0.3 0.6 0.6 0.6
Operator Weight: (lbs) 19 19 19 19 19 22 22
Use Frequency:
(cycles/hour)
70 70 70 60 80 50 50
Pump Flow-Rate:
(liters/min)
1 1 1 0.75 1.5 1.5 1.5
Hydraulic Locking:
(1) = Closing
(2) = Opening and Closing
(1) (2) / / (2) (2) /
Max Leaf Length: (feet) 16 16 18 20 12 18 20
Min Leaf Length: (feet) 9.5 9.5 9.5 12.5 9.5 11.5 11.5
Power Supply 115 VAC ± 10% or 230 VAC +6% -10% 50/60 Hz.
Absorbed Power 220 W
Absorbed Current 1A (230V) or 2A (115V)
Electric Motor 1400 rpm - 4 poles
Thermal Protection
on Windings
248 °F (120°C)
Thrust Capacitor 25uF / 115 V or 8uF / 230 V
Ambient Operating
Temperature Range
-
4°F +131°F (-20 °C +55°C)
Protection Class IP55
1 DESCRIPTION AND TECHNICAL SPECIFICATIONS
The FAAC Model 400 Swing Gate Operator consists of an
electric pump and a hydraulic piston which transmits drive
to the gate leaf.
Models with hydraulic locking do not require the installation
of electric locks, as they provide mechanical locking of the
leaf when the motor is not operating.
Models without hydraulic locking require the installation of
electric locks to ensure that the leaf is mechanically locked.
FAAC 400 Operators were designed and built to automate
swing leaf gates. Do not use for any other purpose.
Figure 3
1. Operators Mod 400
2. Photocells
3. Electronic control unit
4. Key operated push-button
5. Radio receiver
6. Warning light
7. Electric lock (if necessary)
Table 1: 400 Operator – Technical Specifications
OPERATOR TYPE
STANDARD EG
A
40 1/2 in 50 1/2 in
B
27 1/2 in 32 1/4 in
C
10 1/4 in 15 in
Always separate low voltage wiring from AC power cables.
Use separate conduits to avoid electrical interference.
The installer is responsible for grounding the gate and opera-
tor systems, for providing the main power breaker switch, and
for making sure that the entire gate system meets all applica-
ble electrical codes.
Make sure to locate all controls that operate the gate system
at least 6 ft away from any moving parts.
Figure 2
Figure 1
400 OPERATOR
1.1 DIMENSIONS
1.2 WIRING

Other manuals for FAAC 400

Related product manuals