2.5 BY-PASS VALVES ADJUSTMENT
The Model 400 has an anti-crushing safety device which limits
the operator’s force when an obstacle is encountered while
the gate is moving. Follow these steps to adjust the intervention
threshold of the anti-crushing system:
Lift the protective cap (Fig. 13, Ref.1) and insert the supplied
key (Fig. 13, Ref. 2).
Turn the key 90°clockwise to open the cover.
Lift the cover (Fig. 14).
Remove the screw (Fig. 14, Ref. 3) which secures the knob
and then remove the knob (Fig. 14, Ref. 4).
Locate the force adjustment screws (By-Pass) on the
operator (Fig. 14, Ref. 5 and 6) .
OPEN pressure screw (green wording): gate opening
direction.
CLOSE pressure screw (red wording): gate closing
direction.
To reduce torque, turn screws counter-clockwise.
To increase torque, turn screws clockwise.
Test the bypass adjustment by physically obstructing the
gate during its travel and make corrections as appropriate
When you have finished making adjustments, re-position the
knob (Fig. 14, Ref. 4) and tighten the screw (Fig. 14, Ref. 3).
Close the cover and lock it by turning the key counter-
clockwise.
Figure 11 Figure 13
Figure 12
15.) Connect the power cable to the operator and fasten
the screws (Figure 14A).
3 FINAL OPERATIONS
Finish the installation procedure as follows:
• Close the cover of the release device with the key.
• Remove the vent screw (Fig.12, Ref. 2).
Figure 14
Figure 14A
WARNING: Do not overtighten the screws to
compensate for a damaged gate.
WARNING: Failure to remove the vent screw may
result in erratic operation.