9
2ND LEVEL PROGRAMMING
Display
Function
De-
fault
bo
MAXIMUM THRUST TORQUE:
the motor runs at maximum torque (ignoring
torque regulation) at the initial moment of
movement.
Y = Active
no = Excluded
Y
PF
PRE-FLASHING:
it permits activation of the flashing lamp for 5
secs before the start of movement.
no excluded
OC before each movement
PA at end of pause only
CL before closing
no
SC
SLOW CLOSING:
for setting the entire closing stage at slow
speed.
Y = Active
no = Excluded
no
tr
DECELERATION TIME AFTER LIMIT SWITCHES:
for setting the deceleration time (in seconds)
after the opening and closing limit switches
have operated.
Can be adjusted from 0 to 10 sec. in 1 second
steps.
00 = deceleration excluded
10 = maximum deceleration
03
t
WORK TIME (time-out):
A value should be set from 5 to 10 seconds
longer than the time required for the automated
system to move from the closed position to the
open position, and vice-versa.
Can be adjusted from
0
to
59
sec. in 1 second
steps.
Subsequently, the display changes to show
minutes and tenths of a second (separated by
a dot) and time is adjusted in 10 second steps,
up to the maximum value of 4.1 minutes.
20
FS
FAIL SAFE:
If this function is activated, it enables a function
test of the photocells before any automated
system movement, independently of the
output used. If the test fails, the automated
system does not start the movement.
Y = Active
no = Excluded
no
5.4. 2nd LEVEL PROGRAMMING
To access 2nd LEVEL PROGRAMMING, press push-button F
and, while holding it down, press push-button +:
if you release the + push-button, the display shows the
name of the first function.
if you also release the F push-button, the display shows the
value of the function, which can be changed with keys +
and -.
if you press the F key (and hold it down), the display shows
the name of the next function; if you release it, the value
is shown and can be modified with keys + and -.
when you reach the last function, press push-button F to
exit programming, and the display resumes showing the
inputs status.
o1
OUTPUT 1:
The output can be set to one of the following
functions:
00 FAILSAFE
01 INDICATOR LIGHT (lighted at
opening and pause, flashing at
closing and off when automated
system closed).
02 BEAM LIGHTING (output active
with beam closed and on pause,
inactive with beam open, flashing
during movement)
03 beam CLOSED
04 beam OPEN or in PAUSE, it goes off
during closing pre-flashing.
05 beam MOVING AT OPENING,
pre-flashing included.
06 beam MOVING AT CLOSING, pre-
flashing included.
07 beam STILL
08 beam in EMERGENCY status
09 LOOP1 engaged
10 LOOP2 engaged
1 1 OPEN for 624 SLAVE
12 CLOSE for 624 SLAVE
13 beam DETACHED
14 FAAC-CITY lights
15 FAAC-CITY buzzer
16 FCA engaged
17 FCC engaged
18 interlock
00
P1
OUTPUT 1 POLARITY:
For configuring the output polarity status.
Y = N.C. polarity
no = N.O. polarity
Note: if the output is set to FAIL-SAFE (
00 )
leave the default value
no.
no
o2
OUTPUT 2:
See output 1
03
P2
OUTPUT 2 POLARITY:
See output 1 polarity
no
o3
OUTPUT 3:
See output 1
01
P3
OUTPUT 3 POLARITY:
See output 1 polarity
no
o4
OUTPUT 4 / BUS:
If set at
00 the output is dedicated to
accessories with BUS technology. Refer to
chapter 4.3 on page 5 for an explanation.
This output retains the possibility of
configuration of output 1 with the exception
of functions
11, 12 which in this case have
no effect.
00
P4
OUTPUT 4 POLARITY:
For configuring the output polarity status.
Y = N.C. polarity
no = = N.O. polarity (for BUS)
no
ENGLISH