EasyManua.ls Logo

FAAC 624 BLD - 13 Function Logic Tables

FAAC 624 BLD
21 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
Tab. 1/b
Tab. 1/a
LOGIC “A PULSES
AUTOMATED SYSTEM
STATUS
OPEN A CLOSE STOP FSW LOOP 1 LOOP 2
CLOSED
opens and
re-closes after
pause time
no effect
no effect
(opening
disabled)
no effect
opens and
re-closes after
pause time
no effect
OPENING
no effect
reverses
immediately at
closing
stops
operation
no effect no effect no effect
OPEN IN PAUSE
recharges pause
time
closes
stops
operation
recharges pause
time
(closing
disabled)
recharges pause
time
recharges pause
time
(closing
disabled))
CLOSING
reverses
immediately at
opening
no effect
stops
operation
reverses
immediately at
opening
reverses
immediately at
opening
reverses
immediately at
opening
STOPPED
closes closes
no effect
(opening and
closing disabled)
no effect
(closing
disabled)
opens and
re-closes after
pause time
no effect
(closing
disabled)
LOGIC “A1” PULSES
AUTOMATED SYSTEM
STATUS
OPEN A CLOSE STOP FSW LOOP 1 LOOP 2
CLOSED
opens and
re-closes after
pause time
no effect
no effect
(opening
disabled)
no effect
opens and
re-closes after
pause time
no effect
OPENING
no effect
reverses
immediately at
closing
stops
operation
closes
immediately at
end of opening
no effect
closes
immediately at
end of opening
OPEN IN PAUSE
recharges pause
time
closes
stops
operation
closes
recharges pause
time
closes
CLOSING
reverses
immediately at
opening
no effect
stops
operation
reverses
immediately at
opening
reverses
immediately at
opening, closes at
pause end
reverses
immediately
at opening,
re-closes when
opening finished
STOPPED
closes closes
no effect
(opening and
closing disabled)
no effect
(closing
disabled)
opens and
re-closes after
pause time
no effect
(closing
disabled)
LOGIC “E” PULSES
AUTOMATED SYSTEM
STATUS
OPEN A CLOSE STOP FSW LOOP 1 LOOP 2
CLOSED
opens no effect
no effect
(opening
disabled)
no effect opens no effect
OPENING
stops
operation
reverses
immediately at
closing
stops
operation
no effect no effect no effect
OPEN
closes closes
no effect
(closing
disabled)
no effect
(closing
disabled)
closes
no effect
(closing
disabled)
CLOSING
reverses
immediately at
opening
no effect
stops
operation
reverses
immediately at
opening
reverses
immediately at
opening
reverses
immediately at
opening
STOPPED
closes closes
no effect
(opening and
closing disabled)
no effect
(closing
disabled)
opens
no effect
(closing
disabled)
Â
In brackets the effects on the other active pulse inputs
13. FUNCTION LOGIC TABLES
Tab. 1/c
ENGLISH

Related product manuals