18
Tab. 1/d
Tab. 1/e
Tab. 1/f
LOGIC “P” PULSES
AUTOMATED SYSTEM
STATUS
OPEN A CLOSE STOP FSW LOOP 1 LOOP 2
CLOSED
opens no effect
no effect
(opening
disabled)
no effect
opens and at end
of opening closes
if disengaged
no effect
OPENING
no effect
closes
immediately at
end of opening
stops
operation
no effect no effect
closes
immediately at
end of opening
OPEN
no effect
(closing
disabled)
closes
no effect
(closing
disabled)
no effect
(closing
disabled)
prevents closure closes
CLOSING
reverses
immediately at
opening
no effect
stops
operation
stops and
continues to
close on release
reverses
immediately at
opening and
closes at end
of opening if
disengaged
stops and
continues to
close on release
STOPPED
opens closes
no effect
(opening and
closing disabled)
no effect
(closing
disabled)
opens and at end
of opening closes
if disengaged
no effect
(closing
disabled)
Â
In brackets the effects on the other active pulse inputs
LOGIC “PA PULSES
AUTOMATED SYSTEM
STATUS
OPEN A CLOSE STOP FSW LOOP 1 LOOP 2
CLOSED
opens and
re-closes after
pause time
no effect
no effect
(opening
disabled)
no effect
opens and at end
of opening closes
if disengaged
no effect
OPENING
no effect
closes
immediately at
end of opening
stops
operation
no effect no effect
closes
immediately at
end of opening
OPEN IN PAUSE
recharges pause
time
closes
stops
operation
recharges pause
time
(closing
disabled)
recharges pause
time
closes
CLOSING
reverses
immediately at
opening
no effect
stops
operation
stops and
continues to
close on release
reverses
immediately at
opening and closes
at end of opening if
disengaged
stops and
continues to
close on release
STOPPED
opens and
re-closes after
pause time
closes
no effect
(opening and
closing disabled)
no effect
(closing
disabled)
opens and at end
of opening closes
if disengaged
no effect
(closing
disabled)
LOGIC “Cn” PULSES
AUTOMATED SYSTEM
STATUS
OPEN A CLOSE STOP FSW LOOP 1 LOOP 2
CLOSED
opens no effect
no effect
(opening
disabled)
no effect opens no effect
OPENING
no effect
closes
immediately at
end of opening
stops
operation
no effect no effect
closes
immediately at
end of opening
OPEN
no effect
(closing
disabled)
closes
no effect
(closing
disabled)
no effect
(closing
disabled)
no effect closes
CLOSING
reverses
immediately at
opening
no effect
stops
operation
reverses at
opening and
closes after
pause time
reverses
immediately at
opening
reverses
immediately at
opening
STOPPED
opens closes
no effect
(opening and
closing disabled)
no effect
(closing
disabled)
opens
no effect
(closing
disabled)