EasyManua.ls Logo

FAAC 780D - Maintenance and Repairs; Regular Maintenance Checks; Transformer-Board Unit Disassembly; Oil Level Checks and Top-Ups

FAAC 780D
22 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34
Fig. 54
Fig. 53
15.REPAIRS
For any repairs, contact the FAAC authorised Repair Centres.
14. MAINTENANCE
Check the operational efficiency of the system at least once
every 6 months, especially as regards the efficiency of the
safety and release devices (including operator thrust force).
14.1. DISASSEMBLING THE TRANSFORMER-BOARD UNIT
If you have to disassemble the transformer-board unit, proceed
as follows:
Remove all terminal boards and connectors from the board.
Unscrew the 3 securing screws of the board and the 2 of the
transformer. Lift the unit up and gently remove the transformer
from the couplings on the board as shown in Fig. 53.
14.2. OIL TOP-UPS
Periodically check oil level inside the operator.
A once-a-year check is enough for medium or low use
frequency. For heavier duty, every 6 months is recommended.
To access the tank, temporarily remove the oil filling plug (Fig.
54).
Oil level (visually checked) must be in line with the copper
windings of the electric motor.
To top up, pour in oil up to the required level.
Use FAAC XD 220 oil only.