8
E1 mode: How the gate leaf behaves for a given
signal
Leaf
Status
Activating
Signal
Stop Signal Reversing
Device
closed opens
1
no effect no effect
opening stops stops no effect
opened closes
1
no effect no effect
closing opens stops opens
stopped closes
1
(opens
1
when
reversing
device is
triggered)
no effect no effect
A1 mode: How the gate leaf behaves for a
given signal
Leaf
Status
Activating
Signal
Stop Signal Reversing
Device
closed opens and
then closes
after pause
time
1
no effect no effect
opening no effect stops no effect
opened closes after
5 sec
2
pause count
stops
interrupts
pause count
till device is
no longer
triggered
closing opens stops opens
stopped closes
1
no effect no effect
S1 mode: How the gate leaf behaves for a given
signal
Leaf
Status
Activating
Signal
Stop Signal Reversing
Device
closed opens and
then closes
after pause
time
1
no effect no effect
opening closes stops no effect
opened closes
immediately
1,2
pause count
stops
when device
is no longer
triggered,
closes after
5 sec
closing opens stops stops;
opens when
device is no
longer
triggered
1
stopped closes
1
no effect no effect
S2 mode: How the gate leaf behaves for a given
signal
Leaf
Status
Activating
Signal
Stop Signal Reversing
Device
closed opens and
then closes
after pause
time
1
no effect no effect
opening closes stops no effect
opened closes
immediately
1,2
pause count
stops
interrupts
pause count
till device is
no longer
triggered
closing opens stops stops;
opens when
device is no
longer
triggered
1
stopped closes
1
no effect no effect
1
Gate movement begins after 5 sec if pre-flashing has been selected.
2
If you signal the gate during pre-flashing, the pause count restarts.