B614 34 732998 - Rev.A
OUT 4
OUT 3
OUT 2
OUT 1
1
2
3
4
5
6
1
2
5
4
3
1
2
OPEN
+24V
GND
EMER
+24V
GND
STOP
CLOSE
J6
J6 J20
BUS
BUS
GND
LAMP
OUT 4
OUT 3
OUT 2
OUT 1
+24V
LAMP
PE
N
L
N
L
6 A
OPEN
1
2
3
4
5
6
+24V
GND
EMER
STOP
CLOSE
LOOP 2
LOOP 2
LOOP 1
LOOP 1
XF 433-868
AC MAIN
ENC
TRAFFIC
LAMP
LIGHT
BEAM
COM
BLR
BLG
MOT
MOT
M
5
6
6
TXRX
Translation of the original instructions
ENGLISH
6.2 CONNECTIONS
F
Before making electrical connections, cut off the
automation power supply. If the disconnect switch
is not in view, apply a warning sign stating “WARNING
- Maintenance in Progress”.
Li
In Master-Slave configuration see § 10.
CONTROL DEVICES
(36) Connect the devices to the terminal board
J6 of the board.
Li
Multiple NO contacts on same input must be con-
nected in parallel. Multiple NC contacts on same input
must be connected in series.
TERMINAL BOARD J6:
1 OPEN
NO contact, connect a button or other pulse
giver that commands the opening of the
barrier, by closing a contact
2 CLOSE
NO contact, connect a button or other pulse
giver that commands the closure of the
barrier, by closing a contact
3
STOP
Configured as STOP (default):
NC contact, connect a button or other pulse
giver that commands the stopping of the
barrier, by opening a contact
Li
If NO device is connected, make
a jump with GND
FSW-CL
Configured as FSW-CL (see SP function in
Advanced programming):
NC contact, connect a photoelectric cell or
other device that commands the inversion
on opening, by opening a contact during
the closure
Li
If NO device is connected, make
a jump with GND
4 EMER
NC contact, connect a button or other pulse
giver that commands the emergency opening
of the barrier, by opening a contact
Li
If NO device is connected, make
a jump with GND
7 GND
Accessories power supply negative and
common contact (1 A max.)
8-9 +
Accessories power supply positive 24 V
"
(1 A max.).
STOP input configured as FSW-CL
For the connection of photocells with relay contact, it
is necessary to configure the STOP input as FSW-CL.
Connect the negative of the transmitter (TX) power
supply of the photocells to an OUT output configured