B614 37 732998 - Rev.A
Translation of the original instructions
ENGLISH
7. STARTUP
RISKS
PERSONAL PROTECTIVE EQUIPMENT
!
During operation there is a risk of cutting, crushing
or the total loss of hands due to the moving parts
inside the box.
If two barriers are installed in the following configu-
ration Master-Slave, before beginning the start up
of the Master, it is necessary to have configured the
Slave barrier (see § 10).
1. Check that the B614 is locked.
2. Power up the plant (Master barrier). The board
lights up and the display then comes on:
- firmware version (2 digits separated by a point)
-
SO flashing if a set-up or the automation status
is requested
3. Check the status of the LEDs at rest (see § 11.1).
Li
The BUS 2easy LEDs must be checked after the devices
have been registered.
4. Memorise the radio controls present on the plant
(sees § 9.3).
5. Program E614 without performing the set-up.
!
For the barrier to work properly, set the parameter
cF dependent on the beam length.
6. Register the BUS 2easy devices, if they are installed
(see § 9.4).
7. Check the barrier's direction of travel (see § 11.2).
8. Perform the set-up (see § 7.3).
9. If the XBAT 24 battery is being used:
- Cut off the plant's power supply
- Connect the XBAT 24 battery
- Switch on power to the system.
7.1 PROGRAMMING
BASIC PROGRAMMING
1. Press and hold down F until the first basic
function appears. (Each function is displayed
as long as F remains pressed).
F
2. Release: the value of the function appears
(default or programmed).
F
3. Use the + or
-
button to modify the value.
4. Press F to confirm the value displayed. Go
to the next function. The modified value
becomes effective immediately.
F
Proceed in the same way for all the functions. The last function
(
St) allows you to close the program.
5. In
St select Y or no using the +/
-
buttons:
Y = save the new program
no = DO NOT save the new program
6. Press F to confirm and close the program. It returns to the
automation status view.
To exit from the programming mode at
any time:
press and hold down F and then
-
as well to
move directly to
St.
F
+