17
ENGLISH
od
LLEAF DELAY AT OPENING:
Opening of leaf 2 is delayed with respect to leaf 1,
avoiding thus interferences between the leaves.
Y = active
no = excluded
Y Y Y Y Y Y
t
WORK TIME (time-out):
We advise you to set a value longer than the time re-
quired by the gate to open and close completely.
Can be adjusted from 01 to 59 sec. in 1 second steps.
Next, the viewing changes in minutes and ten seconds
(separated by a dot) and time is adjusted in 10 second
steps, up to the maximum value of 9.5 minutes.
4.1 4.1 4.1 4.1 4.1 4.1
r8
SPACE OF TRAVEL STOP SEARCH:
The set level, from 01 to 50, adjusts the space of the
search for the travel stop referred to total travel of the
leaves. For the default values 0-1-2-4, the value
50 corresponds to 40% of total travel, whereas for the
default values 3-5, the value 50 corresponds to 20%
of total travel.
Leaves do not reverse in the space of the search for the
travel stop in the event of an obstacle.
20 20 20 08 20 08
cS
FINAL CLOSING THRUST:
The motors are run at maximum power to facilitate cou-
pling with the electric lock (over pushing stroke).
Y = active
no = excluded
Other more detailed programming pos-
sibilities are feasible by programming with
a PC (see dedicated instructions).
no no no no no no
rS
REVERSING STROKE AT OPENING:
When the gate is closed before opening, the motors
push to close to facilitate uncoupling the electric clock
(reversing stroke).
Y = active
no = excluded
Other more detailed programming pos-
sibilities are feasible by programming with
a PC (see dedicated instructions).
no no no no no no
SF
SOFT TOUCH:
After touching the travel stop point, the leaves reverse
and then rest gently.
Y = active
no = excluded
This function can be useful to respect
the impact curve specified by current
standards.
Ot her more de tail ed prog ramming
possibilities are feasible by PC programming
(see dedicated instructions).
no no no no no no
PF
PRE-FLASHING:
Enables you to select 5 types of pre-flashings of 3 sec.
duration.
no = no pre-flashing.
OC = pre-flashing before every movement.
CL = pre-flashing before a closing motion.
OP = pre-flashing before an opening motion.
PA = pre-flashing at end of pause only
Other more detailed programming pos-
sibilities are feasible by programming with
a PC (see dedicated instructions).
no no no no no no
Display Function
Default
0
Default
1
Default
2
Default
3
Default
4
Default
5