2 WARNINGS
Attention: Before attempting any work on the control unit (connections, maintenance), always turn off power.
- Install, upstream of the system, a differential thermal breaker with adequate tripping threshold,
- Connect the earth cable to the relevant terminal (see fig.5).
- Always separate power cables from control and safety cables (push-button, receiver, photocells, etc.). To avoid any
electrical disturbance, use separate sheaths or a screened cable (with the screen earthed).
3 LAYOUT AND COMPONENTS OF E124
3.1 INPUTS DEFAULT SETTING
Terminal-board J4
IN1 OPEN A N.O. contact
IN2 OPEN B N.O. contact
IN3 STOP N.C. contact
IN4 FSW OP N.C. contact
IN5 FSW CL N.C. contact
Connector J13 – XF Module (OMNIDEC)
Channel 1 OPEN A
Channel 2 OPEN B
Connector J14 - Radio
Channel 1 RP OPEN A
Channel 2 RP2 OPEN B
Fig. 7