16
ENGLISH
rL
DECELERATION:
Adjusts deceleration space as a percentage of the
total travel of the leaves. Adjustable from 00 to 99 %.
in 1% steps.
00 = no deceleration
01 = minimum deceleration space
99 = maximum deceleration space
Other more det aile d programming
possibilities are feasible by PC programming
(see dedicated instructions).
30 30 30 20 20 20
St
AUTOMATED SYSTEM STATUS:
Exit from programming, storage of data and return to the automated system status view
00 = CLOSED
01 = OPEN
02 = Idle then “OPENS”
03 = Idle then “CLOSES”
04 = In “PAUSE”
05 = At opening stage
06 = At closing stage
07 = FAIL SAFE in progress
08 = verification of BUS-2EASY devices in progress
09 = Pre-flashing then “OPENS”
10 = Pre-flashing then “CLOSES”
11 = Opening in EMERGENCY status
12 = Closing in EMERGENCY status
Display Function
Default
0
Default
1
Default
2
Default
3
Default
4
Default
5
7.2. 2
nd
LEVEL PROGRAMMING
To access 2
ND
LEVEL PROGRAMMING, press push-button F and, while holding it down, press push-button
+
:
if you release the + key, the display shows the name of the first second level function (if the dF value persists, this means
that programming was effected from the PC).
if you also release the F push-button, the display shows the value of the function, which can be changed with keys + and -.
if you press the F key (and hold it down), the display shows the name of the next function; if you release it, the values is
shown and can be modified with keys + and -.
when you reach the last function, press the F push-button to exit programming, and the display resumes showing the
automated system status.
If programming via the PC with personalised password was effected, you CANNOT enter 2
nd
level
programming.
•
•
•
•
2
nd
LEVEL PROGRAMMING
Display Function
Default
0
Default
1
Default
2
Default
3
Default
4
Default
5
bo
MAXIMUM POWER AT THRUST:
The motors run at maximum power for the time set
(ignoring the selected power level F1 and F2) during
motion thrust.
Adjustable from 00 to 06 seconds in 1-second steps.
Ot her more de tail ed prog ramming
possibilities are feasible by PC programming
(see dedicated instructions).
02 02 02 02 02 02
EL
ELECTRIC LOCK ON LEAF 2:
The board has a terminal dedicated to the connection
of an electric lock. Normally the electric lock must be
connected to leaf 1. If the electric lock is located on
leaf 2, adjust the parameter.
Y = electric lock on leaf 2
no = electric lock on leaf 1
no no no no no no
cd
LEAF DELAY AT CLOSING:
Adjusts leaf delay at closing.
Adjustable from 00 to 60 seconds in 1-second steps.
00 = no delay
01 = minimum delay
60 = maximum delay
05 05 05 05 05 05