Tab. 10/b
LOGIC “A PULSES
AUTOMATED SYSTEM STATUS
OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
CLOSED
opens and closes
after pause time
opens released
leaf and closes
after pause time
no effect
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
OPENING no effect (1) no effect
recloses leaves
immediately
stops operation
reverses at
closure
no effect
stops and opens
at release (saves
CLOSE)
OPEN IN PAUSE
recharges
pause time (1)
recharges
pause time of
released leaf
recloses leaves
immediately
stops operation no effect
recharges
pause time
(CLOSE disabled)
recharges
pause time
(CLOSE disabled)
CLOSING
reopens leaves
immediately
reopens leaves
immediately
no effect stops operation no effect
reverses at opening
(see 2
nd
level
prog.)
stops and opens
at release (saves
CLOSE)
BLOCKED closes leaves closes leaves closes leaves
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE
disabled)
Tab. 10/d
LOGIC “EP PULSES
AUTOMATED SYSTEM STATUS
OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
CLOSED opens the leaves
opens released
leaf
no effect
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
OPENING
stops operation
(1)
stops operation
recloses leaves
immediately
stops operation
immediately
reverses at
closure
no effect
stops and opens
at release
(OPEN stops -
saves CLOSE)
OPEN
recloses leaves
immediately (1)
recloses leaves
immediately
recloses leaves
immediately
no effect
(OPEN/CLOSE
disabled)
no effect
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE
disabled)
CLOSING stops operation stops operation no effect stops operation no effect
reverses at opening
(see 2
nd
level
prog.)
stops and opens
at release
(OPEN stops -
saves CLOSE)
BLOCKED
restarts moving in
opposite direction.
Always closes after
STOP
restarts moving in
opposite direction.
Always closes after
STOP
closes leaves
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(CLOSE disabled)
no effect
(OPEN stops -
saves CLOSE)
13 FUNCTION LOGICS
Tab. 10/a
LOGIC “E” PULSES
AUTOMATED SYSTEM STATUS
OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
CLOSED opens the leaves
opens released
leaf
no effect
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
OPENING
stops operation
(1)
stops operation
rerecloses
leaves
immediately
stops operation
immediately
reverses at
closure
no effect
stops and opens at
release (OPEN stops
- saves CLOSE)
OPEN
rerecloses
leaves
immediately (1)
rerecloses leaves
immediately
rerecloses
leaves
immediately
no effect
(OPEN/CLOSE
disabled)
no effect
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE
disabled)
CLOSING
reopens leaves
immediately
reopens leaves
immediately
no effect stops operation no effect
reverses at opening
(see 2
nd
level
prog.)
stops and opens at
release (OPEN stops
- saves CLOSE)
BLOCKED closes leaves closes leaves closes leaves
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(CLOSE disabled)
no effect
(OPEN stops -
saves CLOSE)
CLOSE command can only be active from
PC
(1) if the cycle began with OPEN-B (released leaf), both leaves are activated at opening
(1) if the cycle began with OPEN-B (released leaf), both leaves are activated at opening
(1) if the cycle began with OPEN-B (released leaf), both leaves are activated at opening
(1) During the partial opening cycle an OPEN A pulse causes total opening
Tab. 10/c
LOGIC A1”
PULSES
AUTOMATED SYSTEM STATUS
OPEN A OPEN B
CLOSE STOP FSW OP FSW CL FSW CL/OP
CLOSED
opens and closes
after pause time
opens the gate partially
and closes after pause
time
no effect
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
OPENING no effect (1) no effect
re-closes the gate
stops operation
(see 2
nd
level
prog.)
continues to open
and recloses
immediately
stops and on release
opens, then closes
immediately
OPEN IN PAUSE
recharges
pause time (1)
r
recharges
pause time
B
re-closes the gate
stops operation no effect
stops and closes
immediately on release
at the end of the pause,
closes on release
CLOSING
re-opens the gate
re-opens the gate
no effect stops operation no effect
reverses at opening
(see 2
nd
level
prog.)
stops and opens on
release, closes after
pause time
BLOCKED
closes the gate closes the gate closes the gate
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE
disabled)