28
ENGLISH
Tab. 10/m
LOGIC “C MAINTAINED COMMANDS PULSES
AUTOMATED SYSTEM STATUS
OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
CLOSED opens the leaves no effect no effect
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
OPENING no effect closes leaves closes leaves stops operation
reverses at
closure
no effect
stops and, at
release, closes
(saves
OPEN/CLOSE)
OPEN no effect closes leaves closes leaves
no effect
(OPEN/CLOSE
disabled)
no effect
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE
disabled)
CLOSING opens the leaves no effect no effect stops operation no effect
reverses at opening
(see 2
nd
level
prog.)
stops and opens
at release
(saves
OPEN/CLOSE)
BLOCKED opens the leaves closes leaves closes leaves
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE
disabled)
Tab. 10/n
LOGIC “At” (2) PULSES
AUTOMATED SYSTEM STATUS
OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
CLOSED
opens and closes
after pause time
opens released
leaf and closes
after pause time
no effect
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
OPENING no effect (1) no effect
recloses leaves
immediately
stops operation
reverses at
closure
no effect
stops and opens
at release (saves
CLOSE)
OPEN IN PAUSE
recharges
pause time (1)
recharges
pause time
recloses leaves
immediately
stops operation no effect
recharges
pause time
(CLOSE disabled)
recharges
pause time
(CLOSE disabled)
CLOSING
reopens leaves
immediately
reopens leaves
immediately
no effect stops operation no effect
reverses at opening
(see 2
nd
level
prog.)
stops and opens
at release (saves
CLOSE)
BLOCKED closes leaves closes leaves closes leaves
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE
disabled)
Tab. 10/i
LOGIC “B” PULSES
AUTOMATED SYSTEM STATUS
OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
CLOSED opens the leaves no effect no effect
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
OPENING no effect closes leaves closes leaves stops operation
reverses at
closure
no effect
stops and, at
release, closes
(saves
OPEN/CLOSE)
OPEN no effect closes leaves closes leaves
no effect
(OPEN/CLOSE
disabled)
no effect
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE
disabled)
CLOSING opens the leaves no effect no effect stops operation no effect
reverses at opening
(see 2
nd
level
prog.)
stops and opens
at release
(saves
OPEN/CLOSE)
BLOCKED opens the leaves closes leaves closes leaves
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE
disabled)
Tab. 10/l
LOGIC “bC
PULSES AT OPENING / COMMANDS MAINTAINED AT CLOSURE
PULSES
AUTOMATED SYSTEM STATUS
OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
CLOSED opens the leaves no effect no effect
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
OPENING no effect closes leaves closes leaves stops operation
reverses at
closure
no effect
stops and, at
release, closes
(saves
OPEN/CLOSE)
OPEN no effect closes leaves closes leaves
no effect
(OPEN/CLOSE
disabled)
no effect
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE
disabled)
CLOSING opens the leaves no effect no effect stops operation no effect
reverses at opening
(see 2
nd
level
prog.)
stops and opens
at release
(saves
OPEN/CLOSE)
BLOCKED opens the leaves closes leaves closes leaves
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE
disabled)
(1) if the cycle began with OPEN-B (released leaf), both leaves are activated at opening
(1) if the cycle began with OPEN-B (released leaf), both leaves are activated at opening
(1) if the cycle began with OPEN-B (released leaf), both leaves are activated at opening
(2) At power up, the board verifies the inputs, and if an OPEN A or B command is active, it opens the leaf or leaves – otherwise it closes.