E124 19 532365 - Rev.A
Translation of the original instructions
ENGLISH
Advanced function DEFAULT:
0 1 2 3 4 5 6 7
Ad
ADMAP FUNCTION Enables/disables operation in accordance with French
standard NFP 25/362.
Y enabled, no disabled
no
EC
ANTI-CRUSHING SENSITIVITY This function defines the speed with which
the anti-crushing system triggers after an obstacle has been detected.
01 minimum 10 maximum
(* = not modifiable)
01
*
06 06 05 06 05 05 06
US
ULTRA-SENSITIVE OBSTACLE DETECTION This function allows a rigid impact
to be recognised immediately.
Y enabled, no disabled
no no no no Y Y Y no
r8
SEARCH FOR STOP NOT displayed if FC or FA = 01. This function
specifies the angular space in which to search for the opening/closing stop. In
this space, the automation is stopped by a mechanical stop/obstacle and not
by the anti-crushing system.
0.3… 9.9 ° Adjustment step: 0.1 ° Displayed in degrees and tenths of
a degree (separated by a point) up to 9.9°, then it is in degrees.
10… 20 ° Adjustment step: 1 °
10 10 10 4.0 10 4.0 4.0 1
SF
SOFT TOUCH NOT displayed if En = Y. This function causes the leaf to
reverse slightly after the mechanical stop has been detected.
Y enabled, no disabled
no
o1
OUT1 Function of output OUT1.
The letters
tr indicate TIMER programming (from Simply Connect, not
modifiable from the board).
00
00 disabled
01 FAIL-SAFE
02 LED
03 COURTESY LIGHT (timed)
04 ACTIVE ERROR
05 automation OPEN or PAUSED
06 automation CLOSED
07 automation MOVING
08 automation IN EMERGENCY
09 automation OPENING
10 automation CLOSING
11 electric lock function (timed)
12 SAFETY DEVICE ACTIVE
13 TRAFFIC LIGHT function (active during
OPENING and with automation OPEN)
14 timed output that can be activated
from the 2
nd
radio channel OMNIDEC
15 output (step-by-step function) that
can be activated from the 2
nd
radio channel
OMNIDEC
16 active during the movement of motor
1
17 active during the movement of motor
2
18 anti-intrusion alarm
19 battery operation
t1
TIMING OUT1 Displayed if o1 = 03, 11, 14. Sets the duration of
output OUT1, if a timed function is programmed.
1…59 min
Adjustment step:
1 min (if
o1 = 03 or 14), 1 s (if o1 = 11)
02
o2
OUT2 Function of output OUT2 (with the same options as o1).
The letters
tr indicate TIMER programming (from Simply Connect, not
modifiable from the board).
02
t2
TIMING OUT2 Displayed if o2 = 03, 11, 14. Sets the duration of
output OUT2, if a timed function is programmed.
1…59 min
Adjustment step: 1 min if
o2 = 03 or 14 , 1 s if o2 = 11
01