Advanced function DEFAULT:
0 1 2 3 4 5 6 7
AS
MAINTENANCE REQUEST Enables/disables the maintenance alert when the
programmed number of cycles has been reached as specified in the following
functions (
nc, nd) (specific section in chapter § Maintenance).
Y enabled, no disabled
no
nc
THOUSANDS of CYCLES Displays the thousands of cycles that have been
performed.
0065 (programmable if AS=Y)
To reset the cycle counter: press
++ and
--
for 5 s
00
nd
TENS of CYCLES Displays the tens of cycles that have been performed.
0053 (if AS = no)
0099 (programmable if AS = Y)
00
St
LEAVING THE PROGRAMMING MODE
Y Exit without saving the settings
no Exit saving the settings
After having confirmed using button
FF, the display indicates the STATUS of
the automation:
Y
00 CLOSED
01 OPEN
02 STATIONARY THEN
OPENS
03 STATIONARY THEN
CLOSES
04 in PAUSE
05 OPENING
06 CLOSING
07 FAIL- SAFE in progress
08 VERIFYING BUS 2easy
09 PRE-FLASHING and then
OPENS
10 PRE-FLASHING and then
CLOSES
11 OPENING in EMERGENCY
12 CLOSING in EMERGENCY
HP Hold Position
. SLEEP mode (point flash-
ing)

Table of Contents