LOGIC “B” PULSES
SYSTEM STATUS
OPEN A OPEN B STOP FSW OP FSW CL FSW CL/OP
CLOSED opens the leaves no effect
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
OPENING no effect closes leaves stops operation reverses at closure no effect
stops and, at release, closes
(saves
OPEN/CLOSE)
OPEN no effect closes leaves
no effect
(OPEN/CLOSE
disabled)
no effect
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE disabled)
CLOSING opens the leaves no effect stops operation no effect
reverses at opening
stops and opens at release
(saves
OPEN/CLOSE)
BLOCKED opens the leaves closes leaves
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE disabled)
LOGIC “C” CONTINUOS COMMANDS PULSES
SYSTEM STATUS
OPEN A OPEN B STOP FSW OP FSW CL FSW CL/OP
CLOSED opens the leaves no effect
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
OPENING no effect closes leaves stops operation reverses at closure no effect
stops and, at release, closes
(saves
OPEN/CLOSE)
OPEN no effect closes leaves
no effect
(OPEN/CLOSE
disabled)
no effect
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE disabled)
CLOSING opens the leaves no effect stops operation no effect
reverses at opening
stops and opens at release
(saves
OPEN/CLOSE)
BLOCKED opens the leaves closes leaves
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE disabled)
28