CLASS I - RESIDENTIAL VEHICULAR GATE OPERATOR
A vehicular gate operator (or system) intended for use in garages or parking areas associated with a residence of
one to four single families.
UL325 Gate Operator Classifications
CLASS II - COMMERCIAL / GENERAL ACCESS VEHICULAR GATE OPERATOR
A vehicular gate operator (or system) intended for use in commercial locations or buildings such as multi-family
housing units (five or more single family units), hotel, garages, retail store, or other buildings accesible by or servicing
the general public.
CLASS III - INDUSTRIAL / LIMITED ACCESS VEHICULAR GATE OPERATOR
A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loa-
ding dock area or other locations not accessible by or intended to service the general public.
CLASS IV - RESTRICTED ACCESS VEHICULAR GATE OPERATOR
A vehicular gate operator (or system) intended for use in guarded industrial locations or buildings such as an airport
security area or other restricted access locations not servicing the general public, in which unauthorized access is
prevented via supervision by security personnel.
This FAAC swing gate operator is supplied with two warning
signs to alert people that a possible hazard exists and that
appropriate actions should be taken to avoid the hazard
or to reduce exposure to it.
Permanently install one warning sign on each side of the
gate so they are fully visible to traffic and pedestrians.
Use appropriate hardware such as metal screws (not sup-
plied) to permanently install each warning sign.
Installing the Warning Signs

Other manuals for FAAC S418

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FAAC S418 and is the answer not in the manual?

FAAC S418 Specifications

General IconGeneral
Power Supply230V AC (+6% -10%) 50Hz
Motor Voltage24V DC
Operating Temperature-20°C to +55°C
Protection ClassIP54
Limit Switch TypeMagnetic
Control Voltage24V DC