Procedure Command sequence
1) Give a long (>2 s) stop impulse
with the motor stopped.
After 2 seconds, the motor will perform the
movement into position.
Note: in motors with electronic limit switches
the proper positioning is ensured only if the blind
starts from the upper limit position.
Procedure Command sequence
1) Press the A+B buttons for at
least 2 s.
The motor will immediately perform a brief
confirmation movement and after 2 s will start
again in ascent.
2) Wait for the blind to ascend
completely.
The motor is now running in dead man mode,
enabling the fine adjustment of the first middle
position.
3) Con rm the position by
pressing B for 2 s.
The motor will perform three (3) confirmation
movements.
FIRST MIDDLE POSITION
This optional function enables the blinds to be moved to a first preferred middle
position. The first middle position is memorized as descent time starting from the
upper limit switch.
SETTING FIRST MIDDLE POSITION
MOVEMENT TO THE FIRST MIDDLE POSITION
DELETING THE FIRST MIDDLE POSITION
2 sec
2 sec
Positioning2 sec
Adjustment
+
A
B
.....
+
A B
B
B
B
.....
B
4 sec
+
A
B
.....
+
A B
TM2 X R COMPACT 31 A4518_6H81_Rev.A
EN