3) To open the door, remove the screws C (see fig. 11). The door
opening is limited; Remove the door for more space (lift and pull
forward). Be sure that there are no fingerprints on the glass! It is not
possible to remove those prints once they are burned in the glass.
4) Take the box with the log set out of the combustion chamber.
5) Like in the previous models, place the right flue restrictor in the
combustion chamber (see fig. 13). To determine the right flue
restrictor, see paragraph 4.2 and 4.3.