ELECTRICAL REQUIREMENTS
A 120 volt, 60 Hz AC-only electrical supply is required on a separate 15 amp fused circuit. A time-delay fuse or circuit breaker
LVUHFRPPHQGHG7KHIXVHPXVWEHVL]HGSHUORFDOFRGHVLQDFFRUGDQFHZLWKWKHHOHFWULFDOUDWLQJRIWKLVXQLWDVVSHFL¿HG
RQWKHVHULDOUDWLQJSODWHORFDWHGLQVLGHWKHXQLWQHDUWKH¿HOGZLULQJFRPSDUWPHQW
ELECTRICAL INSTALLATION WITH WIRING BOX
THIS UNIT MUST BE CONNECTED WITH COPPER WIRE ONLY. Wire sizes must conform to the requirements of the
National Electrical Code, ANSI/NFPA 70 - latest edition, and all local codes and ordinances. Wire size and connections
must conform with the rating of the appliance. Copies of the standard listed above may be obtained from:
National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
7KLVDSSOLDQFHVKRXOGEHFRQQHFWHGGLUHFWO\WRWKHIXVHGGLVFRQQHFWRUFLUFXLWEUHDNHUWKURXJKÀH[LEOHDUPRUHG
or nonmetallic sheathed copper cable. Allow some slack in the cable so the appliance can be moved if servicing
is ever necessary. A UL Listed, 1/2" conduit connector must be provided at each end of the power supply cable
(at the appliance and at the junction box).
When making the electrical connection, cut a 1 1/4" hole. A hole cut through wood must be sanded until smooth.
A hole through metal must have a grommet.
• Electrical ground is required on this Range Hood.
• If cold water pipe is interrupted by plastic, nonmetallic gaskets or other materials, DO NOT use for
grounding.
• DO NOT ground to a gas pipe.
• DO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral or grounding circuit could
result in electrical shock.
&KHFNZLWKDTXDOL¿HGHOHFWULFLDQLI\RXDUHLQGRXEWDVWRZKHWKHUWKH5DQJH+RRGLVSURSHUO\
grounded.
)DLOXUHWRIROORZHOHFWULFDOUHTXLUHPHQWVPD\UHVXOWLQD¿UH