Fagor ACS Series - 5.3 Electrical Enclosure Diagram

Fagor ACS Series
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AC Brushless Servo Drive System Manual Ver: 0002
ACa - 28 / 32
Preliminary
5.3 ELECTRICAL ENCLOSURE DIAGRAM
This is a sample diagram for an
electrical enclosure. It may be
modified to meet the needs of a
particular application.
It includes a simple circuit to power
the brake of the FXM.
Warning: When using an
autotransformer, the secondary must
have a star connection with its
middle point connected to ground.
Fuses are MANDATORY.
The delay when disconnecting the D3 contacts
serves for:
- the "Drive_Enable" to stay active while the motor
is braking at maximum torque.
- for the brake to hold the motor after it has
stopped.
If the system moves a vertical axis, it should be
compensated for (with counterweight).