EasyManua.ls Logo

Fagor AXD 1.25 - Page 278

Fagor AXD 1.25
386 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
312
8.
INSTALLATION
System installation
278
DDS
HARDWARE
Ref.1310
Adjust the modules through the RS-232 serial line using the application
for PC (WinDDSSetup).
Electrical precautions
Once the installation is completed and before doing anything with the servo
drive system:
INFORMATION. Remember that FAGOR provides all the cables needed
for the installation. If the user chooses to make his own cable, - see chapter
7. CABLES - that indicates the pinout of the connectors at both ends, me-
chanical characteristics and other considerations.
INFORMATION. In order for the FAGOR Servo System to meet the Euro-
pean Directive on Electromagnetic Compatibility 2004/108/EC, the mod-
ules installation rules must be strictly followed regarding:
Installation of the “MAINS FILTER A”.
Electrical installation of the power stage: wiring to mains and motor-
drive power connection.
i
i
WARNING. The system must always be installed before applying voltage
according to the EN 60204-1 standard. Ignoring it may cause serious inju-
ries, even death.
WARNING.
Always disconnect all power supplies, including the external power that
feeds the control board that could be present.
Wait at least 4 minutes until the capacitors of the DC bus are fully dis-
charged. Make sure that the DC BUS voltage is lower than 42 V DC.
Install and close all covers and ground the drive system before applying
voltage
Turn off the mains voltage using an appropriate switch to achieve a volt-
age-free condition.
MANDATORY. The cross section of the protective ground conductor must
comply with the applicable standards. Ground the cable shields at both
ends; however, the shields are not protective ground conductors.