EasyManua.ls Logo

Fagor AXD 1.25 - Page 59

Fagor AXD 1.25
386 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Power supplies
POWER SUPPLIES
Regenerative power supplies
2.
59
DDS
HARDWARE
Ref.1310
Terminal strip to connect the Ballast resistor
Regenerative power supplies also have a small Ballast Circuit for dissipat-
ing energy in case of an emergency. This emergency is issued when
there is no connection to mains and the Ballast circuit activating voltage is
exceeded. See table T. H2/14 in this chapter. Here are the two possible
configurations:
Removing this jumper between Ri and L+ (factory setting) and not connect-
ing an external resistor between Re and L+ generates error code E215 or
E304 on the display.
The following table shows the values for gap, tightening torque, sections
and other interesting data of the feed-through terminals blocks for connect-
ing the ballast resistor:
These power supplies carry a protection against over-temperature which
triggers error E301 on the display when reaching 105 °C (221 °F).
Derating curves
The power that may be dissipated through the internal ballast resistor lo-
cated inside the power supply XPS-25 depends on the ambient tempera-
ture as determined by the derating curve.
The performance of the internal Ballast resistor of the regenerative power
supply XPS-65 does not suffer at high temperatures.
F. H2/20
Ballast resistor connection configurations.
T. H2/17 Technical data of the feed-through terminal blocks for connect-
ing the ballast resistor.
Connector data XPS-25 XPS-65
Min/max tightening torque (N·m) 0.6/0.8 0.6/0.8
Screw thread M3 M3
Min./max. section (mm²) 0.2/4 0.2/4
Rated current In (A)
32 32
F. H2/21
Derating curve of regenerative power supplies XPS-25.
Configuration of the
internal resistor
Configuration of the
external resistor
L-
L+
L-
L+
XPS-25
XPS-65
XPS-65
XPS-25
CONTROL
Ri Re L+ Ri Re L+
CONTROL
R.int
R.int
R.ext
ER+TH-X/X
ER+TH-18/X+FAN
INTERNAL BALLAST
POWER (W)
XPS-25
600
520
35/95 45/113
°C/°F

Related product manuals