BCSD-100/116 Digital Brushless AC Servo Drive system - Ref. 1809
Parameter
No.
Name Unit
Setting
Range
Factory
Setting
Setting
Invalidation
Pn517 Input port signal inversion 0 ~ 1111 0 Immediately
Pn518 Reserved
Pn519 Reserved
Pn520 Reserved
Pn521
If connect externally regenerative
resistor.
0: connect externally regenerative
resistor between B1 and B2
1: does not connect externally
regenerative resistor, relay on
internal capacitance
0 ~ 1 1 Immediately
Pn522 Reserved
Pn523 Reserved
Pn700
Hex
Pn700.0: MODBUS communication
baud rate
Pn700.1: MODBUS protocol selection
Pn700.2: Communication protocol
selection
Pn700.3: Reserved
0 ~ 0x0182 0x0151 After restart
Pn701 MODBUS axis address 1 ~ 247 1 After restart
Pn702 Reserved
Pn703 CAN communication speed 0x0005 0x0004 After restart
Pn704 CAN communication contact 1 ~ 127 1 After restart
Pn840
Hex
Pn840.0: Encoder model selection
Pn840.1: Reserved
Pn840.2: Reserved
Pn840.3: Reserved
0x0003 ~
0x0B06
After restart