02/05/2020 26
SERVICE MANUAL
CONVEYOR BELT
19.2. ELECTRICAL CONNECTION
An AUTHORISED TECHNICIAN should always carry out the appliance’s electrical connection.
The legal standards in force regarding connection to the mains must be taken into account.
• The specifications plate indicates the maximum power in kilowatts (kW) and amperes (A)
for the correct sizing of the installation components (line, power supply cable…).
• Check that the mains voltage corresponds to that indicated on the nameplate.
• Flexible cable with oil-resistant coating, H05RN-F o H07RN-F type must be used.
• The cross-
section of the power cable must be suitable for the rated current of the
machine.
• It is obligatory to earth the appliance. Ensure that the earth connection operates correctly
and efficiently. The manufacturer will not be held liable for damage originated by failure to
observe this requirement.
• Near the appliance and easily accessible to the user, between the power supply and the
appliance, a suitable omnipolar cut-off Circuit Breaker with a minimum contact separation
of 3 mm (0,12 in) must be installed. This switch should be used to disconnect the
appliance during installation, repair, cleaning and maintenance work. It is recommended
that it has lockout-tagout capabilities. The manufacturer will not be held liable for damage
originated by failure to observe this requirement.
• A suitable safety switch / Residual current device must be installed near the appliance
between the power supply and the appliance. The differential protector must be type A-SI
(Super-immunised type A). The manufacturer will not be held liable for damage originated
by failure to observe this requirement.
• The terminal marked with the symbol EQUIPOTENTIAL BONDING on the rear of the
machine must be used for the equipotential connection between different
appliances.
• If any faults are ob
served during the installation, the supplier should be notified
immediately.
• The electrical protection system must be tested before starting the appliance.
The voltage, amperage and connection configuration is given on the specifications plate.
To complete the electrical connection, remove the upper cover protecting the electrical panel in order to access the
connection strip PS. You should also remove the rear vertical protective cover to make it easier to insert the cables.
First turn the mains switch IG to OFF in order to remove the cover. Next, remove the fastening bolts and undo the
cover.
IG
First insert the power cable through the packing gland SR and connect it to the connection strip PS.
The power cable must be secured using the packing glands SR.
It is also possible to complete the electrical connection of the detergent / rinse aid dispensers and/or the limit micro