Drives
3.
Ref.1912
· 159 ·
DDS
HARDWARE
Ballast connector
The Ballast connector located at the bottom of each compact drive allows
enabling the braking resistor (Ballast resistor) and accessing the power DC
BUS (L+, L-).
The following table shows the values for gap, tightening torque (wire entry
holes) and other data regarding the screw-on terminals and plug-in terminals
of the ballast connectors according to drive model:
T. H3/21 Plug-in air connector of the external Ballast resistor ACD|CMC
1.08|1.15 drives. Technical data.
ACD|CMC
1.08 | 1.15
Connector data
Nr of poles 4
Gap (mm) 7.62
Min./max. tightening torque (N·m) 0.5/0.8
Screw thread M3
Min./max. section (mm²) 0.2/6
Rated current In
(A) 41
Connection data
Length to strip (mm) 10
T. H3/22 Plug-in air connector of the external Ballast resistor on ACD|SCD|
CMC 1.25|2.35|2.50 and SCD 2.75 drives. Technical data.
ACD|SCD|CMC SCD
1.25 | 2.35 | 2.50 2.75
Connector data
Nr of poles 3 3
Gap (mm) 7.62 7.62
Min./max. tightening torque (N·m) 0.5/0.8 0.5/0.8
Screw thread M3 M3
Min./max. section (mm²) 0.2/6 0.2/6
Rated current In
(A) 41 41
Connection data
Length to strip (mm) 10 10
x1
x1
x1
WARNING. This connector is only meant for connecting the Ballast resistor.
Never connect a capacitor module because it could destroy the power
module.