20
Ref.1912
DDS
HARDWARE
· 18 ·
0706
New VECON-3 board
Sales models of the glass fiber optic cable SF0-V-FLEX
New ER-18/1000+FAN resistor with fan.
0710
No new hardware has been implemented.
0802
New compact drives: ACD/SCD/CMC 2.50.
There are now 3 switches for selecting the ballast resistor on PS-25B4
power supplies.
New CAPMOTOR-2 board.
0806
The choke RPS-75-3 replaces the choke RPS-75.
There are now 3 switches for selecting the ballast resistor on PS-65A
power supplies.
0811
The following are being replaced:
External 18/1800 W Ballast resistor that is supplied as an accessory
in certain units for 18/1800W with internal thermostat.
External Ballast resistor ER-18/2200 by ER+TH-18/2200 with internal
thermostat.
0905
External 24/750W Ballast resistor that is supplied as an accessory in
certain units for 24/750W with external thermostat.
Changing the power connector for motor connection at SPD 3.200
drives.
1003
The external ballast resistor with fan ER-18/1000+FAN has been
replaced with the new ER+TH-18/1000+FAN with fan and external
thermostat.
The auxiliary APS 24 power supply has been modified and it can now
be connected to the DC bus of the PS, XPS and RPS power supplies.
New regenerative regulated power supply RPS-80.
New modular spindle drive SPD 3.250.
1107
No new hardware has been implemented.
1109
No new hardware has been implemented.
1209
Functional safety. STO safety function.
New spindle compact drive SCD 2.75.
1305
New CHOKE XPS-65-A that replaces the CHOKE XPS-65.
1307
New VECON-4 board.
1406
The Ballast aerial connector has been changed on all compact drives.
New capacitor module ·CM-1.75· (replaces the ·CM-1.60·).
RPS power supplies. RPS mode (boost) and RB6 mode (rectifier).
Mains filter. MAIN FILTER 75A” for RPS-45.
Temperature sensor isolation adapter ·TSIA-1·.
1502
Bus Protection Module ·BPM·.
1601 Reorganization of texts for electrical safety and functional safety.
New mains filter: ·MAIN FILTER 130A-A· for PS-65A.
New commercial models -MDU (dual-use).
1605
Mains filter ·MAIN FILTER 42A-A· for PS-25B4, XPS-25, RPS-20, and
ACD/SCD x.x replacing MAIN FILTER 42A.
Mains filter ·MAIN FILTER 130A-A· for XPS-65 and RPS-75 replacing
MAIN FILTER 130A.
1702
Mains filter ·MAIN FILTER 75A-A· for RPS-45
1710
TÜV SÜD FUNCTIONAL SAFETY certificate update.
1711
No new hardware has been implemented.
1807 Changing the sensor position of the thermostat for the braking resistors
ER+TH-...+ FAN.
Equipment for working in industrial graphite environments:
Power supplies: PS-25B4-C, RPS-20-C,
Drives: AXD 1.15-S0-2-C, AXD 1.25-S0-2-C, AXD 1.35-S0-2-C
CA-D1-D4 adapter cable for the connection of the linear motor or
torque motor feedback to the motor feedback board of the drive.
Manual reference Events

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fagor DDS Series and is the answer not in the manual?

Fagor DDS Series Specifications

General IconGeneral
BrandFagor
ModelDDS Series
CategoryDC Drives
LanguageEnglish

Related product manuals