Connection diagrams
10.
358
Ref.1912
DDS
HARDWARE
· 358 ·
10.18 On-the-fly start/delta connection switching on FM7 spindles, E03|HS3 series
F. H10/33
Diagram of on-the-fly Y/D (start/delta) connection switching for FM7-XXXX-XXX-E03|HS3 motors.
DIGITAL INPUT
X1
X2
GND
I8
I1
N.C.
I2
I3
I4
I5
I6
I7
GND
I16
I9
N.C.
I10
I11
I12
I13
I14
I15
DIGITAL OUTPUT
X1
X2
GND
O8
O1
+24V
O2
O3
O4
O5
O6
O7
GND
O16
O9
+24V.
O10
O11
O12
O13
O14
O15
POWER SUPPLY
FAGOR
PS-65A + APS24 (X2, X3 & X4) 24 V DC, 10 A
PS-25B4 (X4, X5 & X6) 24 V DC, 10 A
XPS-XX (X4, X5 & X6) 24 V DC, 8 A
RPS-XX (X2) 24 V DC, 8 A
24 V (of the FAGOR power voltage)
0 V (of the FAGOR power voltage)
K3
K2
K1
K4
*
GND
CAN L
SHIELD
SHIELD
CAN H
X3
GND
CAN L
SHIELD
SHIELD
CAN H
X2
POWER SUPPLY
4
0
1
F
D
C
B
9
8
7
5
3
ADD MSB
LINE TERM
10
12
ADDRESS
RESET
POWER
SYSTEM READY
+5 ERROR
+5 OVER CURRENT
OVER VOLTAGE
+5V
X1
GND IN
CHASIS
GND IN
+24V IN
SYSTEM
READY
K1
K2
A1
A2
Auxiliary relays - KA3, - KA4. e.g. RP821024
F l ywh eel d i odes D 3, D 4. e.g. 1N 4934
24 V
24 V
OUTPU T 24 V DC
THE STAR/DELTA
SWITCH IS MANAGED
BY THE PLC PROGRAM
AT TH E 8070 CN C
*
24 V
0 V
0 V
24 V
A1
A2
0 V
I10
I11
REMOTE I/O
A1
Flywheel diode
1N4934
CANFagor
INTERFACE
0 V
24 V
O11
O10
A2
A1
A2
- KM2
Star
- KM1
Delta
MPC-4xN
2
U/U1
V/V1 W/W1
U
V
W
MPC-4xN
1
MPC-4xN
1
MPC-4xN
1
MPC-4xN
1
M
3
MPC-4xN
1
X/U2
Y/V2 Z/W2
- KA1
D3
- KA2
D4
- KA4
D3
- KA3
D4
EXTERNAL
AUXI LI ARY
POWER SUPPLY
F l yw h eel d i od e
1N4934
DRIVE SPD
FAGOR
0 V
CH ASSI S
- KM1 contactor: I
(KM1)
>
I
N
( )
I
(KM2)
>
(1/ ) I
N
( )
3


- KM2 contactor:
Important warnings
1. Either an external auxiliary power supply or a FAGOR power supply may be used to supply the 24 V DC.
Never connect both at the same time !
2. To brake the motor in a controlled way during a power failure, make sure that 24 V DC will be supplied to
contactors - KM1 and - KM2 and relays - KA3 and - KA4. This situation is ensured if you have installed a
FAGOR power supply next to an SPD modular drive. If you have installed an external auxiliary 24 V DC power
supply, you must make sure that this condition is ensured.
3. When using a compact SCD drive to govern a spindle motor, you must necessarily install an external auxiliary
power supply to provide the 24 V DC. These compact drives do not have an output 24 V DC connector.
Note. See these currents in chapter 6. Selection, of the FM7/FM9 motor manual.
Sizing of motor power cables
Note. See the necessary cable section according to table of the chapter 4. Installation of the FM7/FM9 motor manual.
Notes. The I/O selected in the figure have been chosen arbitrarily. In general any Ixx and Oxx may be used always
matching the ones used in the PLC.
It is very common to choose I1 and O1 for the external emergency. Therefore, we suggest not to use them for this
application. If they are going to be used, make sure that they have not been set to be used as emergency input and
output.
Sizing of -KM1 and - KM2 power contactors
MPC- 4xN
1

N
1
: section supporting I
N
( )
MPC- 4xN
2
N
2
: section supporting I
N
( )

WARNING. If you decide to install an external auxiliary power supply, make sure
that in case of a power outage, the 24 V DC are ensured to brake the motor
under control preventing it from braking by inertia. Ignoring this warning may
cause personal injury.
* WARNING. Never connect an external
auxiliary power supply and a FAGOR
power supply at the same time.
U1 W1
U2 W2
V2
V1
UVW
UVW
V1 W2
V2 W1
U1 U2
STAR connecti on DELTA connection