Power supplies
2.
94
Ref.1912
DDS
HARDWARE
· 94 ·
Follow this sequence to stop the system without having detected any errors:
Disabling the drives; i.e. disable the Speed Enable of all the axes or the
System Speed Enable.
Disconnecting the power line by opening the contactor -KM1, usually by
pressing the E-STOP button.
NOTE. When detecting an error, it will switch from any state 0, 1, 2 or 3
directly to state 4. From any of the states, it will switch to state 0 if a stop
occurs due to the
NO READY state of any of the drives connected to the
power supply or because the power line has been disconnected or
because the emergency stop button has been pressed or because the
line voltage has dropped.