Do you have a question about the Fahrenheit Technologies Endurance 50F and is the answer not in the manual?
Brand | Fahrenheit Technologies |
---|---|
Model | Endurance 50F |
Category | Furnace |
Language | English |
Important safety warning regarding installation and operation to prevent fire, injury, or death.
Read manual before use, keep fire extinguisher handy, follow codes, ensure clean chimney, and supervise children.
Warnings about house fires from improper installation and carbon monoxide poisoning from improper fuel.
Specifies minimum clearances to combustibles for floor, sides, front, and back for safe operation.
Outlines rules for vent termination location relative to doors, windows, ground, walkways, and combustibles.
Guides on connecting the furnace to existing HVAC systems, including duct size and static pressure limits.
Lists approved fuels like corn, wheat, grain pellets, and cherry pits with descriptions of their types.
Guides on initial startup, burn-in period, handling hot surfaces, and preventing smoke/CO emissions.
Lists and explains common error messages like Loss of Power, Loss of Flame, Loss of Vacuum, and Actuator Limit Errors with solutions.
Instructions for removing ash, clinkers, and cleaning the air box trap door for proper furnace operation.
Steps for cleaning the burn pot and the exhaust clean-out port to maintain performance.
Tasks to perform after the last burn of the season, including cleaning and fuel removal.
Troubleshooting steps for no fuel dispersion, overloading the burn pot, and furnace not burning due to flame loss.
Solutions for 'Loss of Vacuum' and 'Loss of Power' error messages, including checking seals and power connections.
Troubleshoots 'Auger Time-Out' and 'Actuator Limit Error' messages, checking lid closure and actuator movement.
Details what the warranty covers (defects) and excludes (misuse, unauthorized installation, improper fuel).