4. Using the LM
When using the manual operation, do not activate the actuator electrically.
If the actuator can no longer be activated electrically, the manual operation can still be used to open and close the
motor. Use a battery drilling machine and the 6mm/0.24inch hexagonal pin supplied. Place the hexagonal pin in the
drill head, then insert it into the back of the actuator (Figure below).
Manual operation with battry drilling machine
5. Maintaining the LM
Always disconnect power before cleaning the actuator.
Fancom advises cleaning the LM actuator regularly, preferably using an air compressor. This prevents imbalance
and overheating.