Lumina 71 Feed feeding place
19
Status feed place
Readout of the feed place status (value between the brackets):
FREE: Feed place is free to use.
BUSY
: Feed place is currently feeding, you have to wait till this feed place is free.
BLOCK: Feed place may not be used.
And setting to manually set the feed place status:
FREE: The control computer can run the cycle.
BLOCKED: The control computer will skip the cycle.
SKIP
: The control computer will skip the following cycle and then set the status of
this cycle to FREE. The amount intended to be given during this cycle will not be
supplied.
1-TIME, 2-TIMES, 3-TIMES: The control computer will run the following cycle to
supply an amount. Then the status of this cycle will be set to BLOCK.
Curve
Setting of which feed curve is used for feeding.
Curve day
Setting of the curve day number.
Cycle
Setting of the feed cycle.
Animal weight
Setting of the animal weight.
Feeding method Setting of the feeding method (REGISTER, DOSING, DOSE/REGIST).
Day Am.
Setting of the feed amount that will be dosed this day. The value between the brackets
indicates the actual dosing percentage.
Sensor status
Readout of the current sensor status.
Am./Anim
Readout of the calculated daily amount per animal. This amount is based on the dosing
percentage. After adjusting Day Am the dosing percentage will be automatically
recalculated.
Cycle
Readout of the number of feed cycles.
Biorhythm
Setting which biorhythm percentage must be used during a cycle. This percentage
could be positive (+) and negative (-).
The sum of the percentages must be 0%.
The biorhythm change the distribution of the portion during the day. This
enables less feed to be supplied in the evening and more in the morning.
To be dosed
Readout of the feed amount to be supplied during this cycle.
Temporarily supply more feed, e.g. if animal growth is slower than expected.
Enter this when setting up the animals, or later.
Dosed
Readout of the feed amount that already has been dosed out.
Total Readout of the calculated amount by To be dosed and Dosed.