Process Controllers
FAST Lit. Part No. 229-51311 Rev. E (MANAGER) 24SEP2010 Page 7
2005-2010 Food Automation – Service Techniques, Inc. All Rights Reserved
This document contains confidential information. The dissemination, publication,
copying, or duplication of this document without prior written authorization is
strictly prohibited.
Programming the (FASTRON.)
VC-210 Controller
Programming Mode for the Vision Controller is entered by pressing the “P” key for three (3) seconds. Multiple
programming modes are available on the VC-210 as follows:
System
Recipe
ProdName
Library
Alarm
Library
Clock/Date
SMS Activate
Instant On
SCK Address
NOTES:
• Pressing the “P” key saves the previous parameter.
• If no key is pressed within 2 minutes while in Programming mode, the controller will automatically
return to idle mode.
• All scrolling will loop back through allowed values.
Changing the Menu Strip on a (FASTRON.) VC-210
Process Controller
• Turn off the fryer power.
• With a flat screwdriver, remove the two screws that secure the bezel of the
VC-210 in place. Remove the bezel.
• Remove the existing menu strip(s) by lifting the tab and pulling the menu
strip out from the right side of the controller.
• Using the tab as a guide, slide the new menu strip in.
• Replace the bezel and screws that secure it to the controller.
• Turn on the fryer power.
Replacement Parts List
1/4-20X3/4" SLOT RD HD BLK O
NUT 1/4-20 TINNERMAN SPRING