37X INSTALLATION & OPERATION MANUAL
372/373 MODELS
24
7.10 Settings Menu
The SETTINGS menu (Figures 7.15 and 7.16) provides dispenser information and access to some settings that are
adjustable. Available settings options change based on dispenser software.
SERIAL #: Set the serial number of the dispenser (this is used for BevTrakTM reporting).
BARRELS: Provides the number of barrels for the dispenser.
DISPLAY UNITS: Set the units of measurement to IMPERIAL or METRIC.
ALARM: Enabled sold-out audible alarm. Only dispensers ordered with the alarm option will have an alarm
installed despite the presence of this setting in this menu.
REFRIGERANT: Displays the refrigerant–R404-A or R448-A–the dispenser is using.
BEATER ALWAYS ON: For dispensers with the energy savings option to turn off motors intermittently, this
setting, if ENABLED, allows for beater motors to remain on at all times
There are also four additional submenus that can be updated/set-up based on dispenser model to adjust different drink
characteristics.
GAS CONFIGURATION: Used to display and, based on dispenser model, select the gas that will be used in the
dispenser (Figures 7.17, 7.18, and 7.19).
DRINK TYPE CONFIGURATION: Used to configure the drink type (medium or high expansion) based on selected
gas (Figure 7.20). Settings will only be available on dispensers with universal and multi-gas configurations.
EXPANSION ADJUSTMENT: Used to adjust the amount of gas in a drink (Figure 7.21). The range of values is
limited based on the configured gas and drink type.
FREEZE ADJUSTMENT : Used to adjust how frozen the drink is (Figure 7.22).
Figure 7.15 Figure 7.16